Influence of low‐level laser therapy on implant stability in implants placed in fresh extraction sockets: A randomized clinical trial

Abstract: Background: Low-level laser therapy (LLLT) has been suggested to improve primary stability at the early stages of osseointegration in animal models. However, there is still scarce evidence about its influence on implant stability in humans. Purpose: To assess the influence of LLLT on implant stability in implants placed in fresh extraction sockets. Material and methods: A randomized controlled trial was designed according to the SPIRIT guidelines and is reported following the CONSORT. Patients were randomly al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
19
0
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 32 publications
0
19
0
3
Order By: Relevance
“…RFA is used in many clinical studies because of its minimally invasive nature and high reproducibility. [24][25][26][27] The ISQ value can be used to predict failure, and successful results can be obtained when the second stability value is 60 or more. 28,29 For RFA measurements, SmartPeg is installed on the platform, and the stable value for the implant is measured by determining the resonance frequency of the porcelain pulse applied to SmartPeg.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…RFA is used in many clinical studies because of its minimally invasive nature and high reproducibility. [24][25][26][27] The ISQ value can be used to predict failure, and successful results can be obtained when the second stability value is 60 or more. 28,29 For RFA measurements, SmartPeg is installed on the platform, and the stable value for the implant is measured by determining the resonance frequency of the porcelain pulse applied to SmartPeg.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, RFA was used to assess implant stability. RFA is used in many clinical studies because of its minimally invasive nature and high reproducibility 24‐27 . The ISQ value can be used to predict failure, and successful results can be obtained when the second stability value is 60 or more 28,29 .…”
Section: Discussionmentioning
confidence: 99%
“…The application points were divided into two points in the labial region (apical and cervical); two points in the lingual region (apical and cervical); and two points in the previous occlusal direction, resulting in a total dose of 66 J. This PBMT protocol was applied only in the tooth extraction and is based on a previous study ( 16 , 17 ).…”
Section: Introductionmentioning
confidence: 99%
“…Os implantes dentais são bastantes utilizados em pessoas que desejam substituir dentes perdidos ou com falhas, e para se obter boa estabilidade desse implante é preciso que o processo de osseointegração apresente bons resultados. A terapia a laser de baixa intensidade (LLLT) apresenta uma resposta significativa na melhoria dessa estabilidade primária nas fases iniciais da osseointegração (Lobato et al, 2020).…”
Section: Introductionunclassified
“…A fototerapia do laser ocorre devido ao comprimento de onda infravermelho que é absorvido pelo tecido, o que estimula ao redor do local da aplicação várias respostas, como a atividade osteoblástica, bioestimulando a formação do tecido ósseo e redução de processos inflamatórios, essa LLLT também está relacionada com a penetração da luz no comprimento de onda Research, Society and Development, v. 10, n. 3, e31310313322, 2021 (CC BY 4.0) | ISSN 2525-3409 | DOI: http://dx.doi.org/10.33448/rsd-v10i3.13322 (Lobato et al, 2020). Além disso, a laserterapia tem auxiliado a implantodontia oral a reduzir o tempo de cicatrização (Zayed et al, 2020).…”
Section: Introductionunclassified