Influence of Multifocal Intraocular Lenses on Standard Automated Perimetry Test Results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
21
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(22 citation statements)
references
References 24 publications
1
21
0
Order By: Relevance
“…With regard to the influence of multifocal IOLs on VF sensitivity, Aychoua et al have reported that in the multifocal IOLs (TECNIS ® Multifocal ZM900; AMO, AT LISA ® 809M; CarlZeiss Meditec), the MD value of HFA was about 2 dB lower than the monofocal IOLs [ 9 ]. Farid et al also reported that in the multifocal IOLs (TECNIS ® Multifocal ZMB00, ZMA00; AMO, ReSTOR ® SN6AD1; Alcon), the MD value of HFA was about 2 dB lower [ 8 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…With regard to the influence of multifocal IOLs on VF sensitivity, Aychoua et al have reported that in the multifocal IOLs (TECNIS ® Multifocal ZM900; AMO, AT LISA ® 809M; CarlZeiss Meditec), the MD value of HFA was about 2 dB lower than the monofocal IOLs [ 9 ]. Farid et al also reported that in the multifocal IOLs (TECNIS ® Multifocal ZMB00, ZMA00; AMO, ReSTOR ® SN6AD1; Alcon), the MD value of HFA was about 2 dB lower [ 8 ].…”
Section: Discussionmentioning
confidence: 99%
“…It was previously reported that diffractive bifocal IOLs decreased the MD value [ 8 , 9 ]. In this study, we showed the MD value decreased in patients with diffractive bifocal IOLs but the FT value and all VF also decreased significantly compared to the monofocal IOLs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The drawbacks associated with this type of IOL design are loss of contrast sensitivity, increase in higher order aberrations, and night-time glare and halos [8,9]. Aychoua et al [10] recently reported a clinically relevant reduction of visual sensitivity as assessed with standard automated perimetry in patients with MF IOL. Another published paper reported wavy horizontal artifacts on OCT linescanning ophthalmoscopy images in patients with two different types of diffractive MF IOLs, tested with 4,000 Cirrus HD-OCT Ò device (Carl Zeiss Meditec).…”
Section: Discussionmentioning
confidence: 99%
“…The reduction interferes with the assessment of common eye diseases, such as glaucoma and comes on top of the decline of visual sensitivity due to normal aging or age-related eye diseases, thus potentially accelerating visual impairment. 35 …”
Section: Introductionmentioning
confidence: 99%