2020
DOI: 10.1007/s00604-020-04613-z
|View full text |Cite
|
Sign up to set email alerts
|

Influence of temperature variation on spinel-structure MgFe2O4 anchored on reduced graphene oxide for electrochemical detection of 4-cyanophenol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 47 publications
0
9
0
Order By: Relevance
“…The direct relationship is validated by the calibration curve in Figure b with the regression correlation coefficient ( R 2 ) of 0.991. The proposed sensor shows confirmations of remarkable electrocatalytic activity with the attainment of values as low as a detection limit of 0.5 nM and wide linear responses of 0.001–89 μM, and values are calculated using the standard formula The evaluation of the analytical features of the LaV/h-BN-based electrochemical platform (Table ) signifies its efficient performance compared to those of previously reported studies, where, from the i – t curve, it is obtained to be 5 s on average for each and every addition of the analyte. The improved performance of the sensor can be recognized in accordance with the synergistic interactions between LaV and h-BN, the creation of electroactive edge sites, better electronic conductivity, and morphological encapsulation supporting electron transfer.…”
Section: Resultsmentioning
confidence: 74%
“…The direct relationship is validated by the calibration curve in Figure b with the regression correlation coefficient ( R 2 ) of 0.991. The proposed sensor shows confirmations of remarkable electrocatalytic activity with the attainment of values as low as a detection limit of 0.5 nM and wide linear responses of 0.001–89 μM, and values are calculated using the standard formula The evaluation of the analytical features of the LaV/h-BN-based electrochemical platform (Table ) signifies its efficient performance compared to those of previously reported studies, where, from the i – t curve, it is obtained to be 5 s on average for each and every addition of the analyte. The improved performance of the sensor can be recognized in accordance with the synergistic interactions between LaV and h-BN, the creation of electroactive edge sites, better electronic conductivity, and morphological encapsulation supporting electron transfer.…”
Section: Resultsmentioning
confidence: 74%
“…The higher sensitivity of CGO/PEDOT:PSS coated chip could attribute to the good absorption (porous surfaces fabricated with coating), adsorption ability, high catalytic activity and good bio-compatibility of the CGO/PEDOT:PSS/Au/μ-Chip. The CGO/PEDOT:PSS/Au/μ-Chip assembly exhibits very high sensitivity towards 4-CP and extremely lower LOD than other 4-CP sensors, which is presented in Table 2 [ 13 , 20 , 21 ]. The CGO/PEDOT:PSS/Au/μ-Chip sensor is showed an excellent stability and reliability as well.…”
Section: Resultsmentioning
confidence: 99%
“…United States Environmental Protection Agency (US EPA) also declared this 4-CP as a major environmental pollutant [ 9 , 10 ]. 4-CP is also commonly used as an antifungal [ 11 ], insecticidal [ 12 ] agents and its adverse effect has been studied by researchers [ 8 , 13 , 14 ]. Inhalation of 4-CP can harm the central nervous system and disturb the cardiac systems [ 15 ].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations