2021
DOI: 10.1016/j.ohx.2020.e00168
|View full text |Cite
|
Sign up to set email alerts
|

Infrared thermometer on the wall (iThermowall): An open source and 3-D print infrared thermometer for fever screening

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(22 citation statements)
references
References 18 publications
0
19
0
2
Order By: Relevance
“…Non-contact Infrared digital thermometer is used to measure person's body temperature. Non-contact infrared digital thermometers have been used to collect real-time data in strategic entry and exit points for COVID-19 screening purposes [55] . The body temperature can be taken from a safe distance and to avoid physical contact thereby reducing the risk of exposure.…”
Section: Covid-19 Situation Analysis and Social Distancing Tools In Zimbabwementioning
confidence: 99%
“…Non-contact Infrared digital thermometer is used to measure person's body temperature. Non-contact infrared digital thermometers have been used to collect real-time data in strategic entry and exit points for COVID-19 screening purposes [55] . The body temperature can be taken from a safe distance and to avoid physical contact thereby reducing the risk of exposure.…”
Section: Covid-19 Situation Analysis and Social Distancing Tools In Zimbabwementioning
confidence: 99%
“…The voltage is stable at around 4.5 V to 5.00 V. To measure the power consumption of our device, the total current is assumed by 30% for the maximum current and 70% for the minimum current. The power consumption of Lvital device is calculated as follows using Equations 4–6 from [26] . …”
Section: Validation and Characterizationmentioning
confidence: 99%
“…Validasi pengukuran suhu pada iThermowall dilakukan dengan analisis uji-T. Hasil penelitian menunjukkan bahwa Pvalues untuk semua tes lebih signifikan dari 0,05, artinya suhu Celcius rata-rata untuk kedua kelompok (termometer referensi dan iThermowall) adalah serupa. Penelitian ini menyediakan opensource 3-D yang dapat dicetak dan firmware kode sumber lengkap untuk komunitas yang sedang berkembang dan yang kekurangan sumber daya [21] Penelitian Oleh Zuyina Lukluknaningsih (2020) dengan judul Pengaruh Infra Red dengan Massage fisioterapi Terhadap Tingkat Stress Mahasiswa yang sedang Mengerjakan Tugas Akhir. Pada penelitian ini membahas mengenai pengaruh infrared dengan massage fisioterapi terhadap sejumlah mahasiswa yang sedang mengerjakan tugas akhir, berdasarkan wilcoxon test diperoleh nilai Z sebesar -5,253 dengan signifikansi 0, sehingga dapat disimpulkan bahwa pemberian sinar inframerah dengan massage fisioterapi berpengaruh secara signifikan terhadap tingkat stress mahasiswa [22] Penelitian oleh A.Amin (2018) dengan judul Pengaruh Chest Therapy dan Infra Red Pada Bronchopneumonia.…”
Section: Pendahuluanunclassified