2022
DOI: 10.1007/s12149-022-01721-z
|View full text |Cite
|
Sign up to set email alerts
|

Initial evaluation of a new maximum-likelihood attenuation correction factor-based attenuation correction for time-of-flight brain PET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…However, the resolutions of the silicon photomultiplier PET/CT Discovery MI, Digital Biograph Vision PET/CT System, and the Philips Vereos PET/CT System are also approximately 4 mm FWHM (18)(19)(20)(21). Moreover, even if the resolution of the silicon photomultiplier PET scanner is compared with that of the wbPET scanner, there will not be a significant impact on the results of this study because the resolution of the dhPET system is less than 3 mm FWHM (10).…”
Section: Discussionmentioning
confidence: 87%
See 1 more Smart Citation
“…However, the resolutions of the silicon photomultiplier PET/CT Discovery MI, Digital Biograph Vision PET/CT System, and the Philips Vereos PET/CT System are also approximately 4 mm FWHM (18)(19)(20)(21). Moreover, even if the resolution of the silicon photomultiplier PET scanner is compared with that of the wbPET scanner, there will not be a significant impact on the results of this study because the resolution of the dhPET system is less than 3 mm FWHM (10).…”
Section: Discussionmentioning
confidence: 87%
“…Detailed basic specifications of the dhPET system are described elsewhere (10). This TOF-PET system for the head and breast is designed to be less expensive than the conventional wbPET system but with higher sensitivity and spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…Another disadvantage of dbPET is that the mammary gland near the chest wall may sometimes be outside the FOV of dbPET compared to MRI. A new ring-shaped PET scanner with a larger detector diameter than ours has been developed [ 24 ]; it may solve this issue, i.e., reduce blind areas.…”
Section: Discussionmentioning
confidence: 99%
“…During data acquisition, both prompt and delayed events are saved in list-mode format, and a 3D image is reconstructed at an isotropic voxel size of 1.1 mm with a matrix size of 240 (X) × 240 (Y) × 148 (Z). Attenuation and scatter correction are performed with a modified maximum-likelihood attenuation correction factor and single scatter simulation without external radiation exposure [ 13 ].
Fig.
…”
Section: Methodsmentioning
confidence: 99%