2011
DOI: 10.1007/s13361-011-0125-9
|View full text |Cite
|
Sign up to set email alerts
|

Initial Experimental Characterization of a New Ultra-High Resolution FTICR Cell with Dynamic Harmonization

Abstract: A new Fourier transform ion cyclotron resonance (FTICR) cell based on completely new principles of formation of the effective electric potential distribution in Penning type traps, Boldin and Nikolaev (Proceedings of the 58th ASMS Conference, 2010), Boldin and Nikolaev (Rapid Commun Mass Spectrom 25:122-126, 2011) is constructed and tested experimentally. Its operation is based on the concept of electric potential space-averaging via charged particle cyclotron motion. Such an averaging process permits an effec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
161
0
1

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 146 publications
(163 citation statements)
references
References 20 publications
1
161
0
1
Order By: Relevance
“…High resolution mass spectra were acquired with a solarix XR Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR-MS; Bruker Daltonik GmbH, Bremen, Germany) equipped with a 12 T refrigerated actively shielded superconducting magnet (Bruker Biospin, Wissembourg, France), a dual ion source and Paracell analyzer cell (Nikolaev et al, 2011). The samples were ionized by electrospray ionization in positive ion mode (Bruker Daltonik GmbH, Bremen, Germany).…”
Section: Ft-icr-ms Measurementsmentioning
confidence: 99%
“…High resolution mass spectra were acquired with a solarix XR Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR-MS; Bruker Daltonik GmbH, Bremen, Germany) equipped with a 12 T refrigerated actively shielded superconducting magnet (Bruker Biospin, Wissembourg, France), a dual ion source and Paracell analyzer cell (Nikolaev et al, 2011). The samples were ionized by electrospray ionization in positive ion mode (Bruker Daltonik GmbH, Bremen, Germany).…”
Section: Ft-icr-ms Measurementsmentioning
confidence: 99%
“…To the best of our knowledge, this result represents the highest resolving power ever reported for BSA, and promises high performance analysis of even larger proteins [30,31]. We processed Figure 3 in magnitude mode and without apodization for direct comparison with prior work [10]. Note that the data shown in Figure 3 is the result of a single acquisition, whereas the prior record was the result of 100 averaged scans.…”
Section: Ultrahigh Resolutionmentioning
confidence: 99%
“…The mass spectrometer combines a modified Velos Pro [6][7][8] (ThermoFisher Scientific, San Jose, CA, USA) with an NHMFL-designed external linear quadrupole ion trap, quadrupole ion transfer optics, and novel dynamically harmonized ICR ion trap (DHC) [9,10]. The Velos Pro front end offers high sensitivity, efficient ion isolation, precise control of ion number, and both collisional dissociation and front-end electron transfer dissociation (FETD; we use the simpler term BETD^here).…”
Section: Ft-icr Mass Spectrometermentioning
confidence: 99%
“…For a long long time, these demands were only met by the Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR) [1]. However, while providing for unsurpassed performance, especially with recently introduced dynamically harmonized cells [2,3], this method is not free of some drawbacks like the need for high magnetic field cryomagnets incurring significant usage expenses. For this reason, there is growing interest in another design of Fourier transformbased spectrometers-the recently invented orbital ion trap having performance comparable to FT-ICR instruments, which have ion traps without dynamic harmonization.…”
Section: Introductionmentioning
confidence: 99%