2019
DOI: 10.1016/j.ijrefrig.2019.09.001
|View full text |Cite
|
Sign up to set email alerts
|

Innovative fully integrated transcritical R744 refrigeration systems for a HFC-free future of supermarkets in warm and hot climates

Abstract: General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0
6

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 39 publications
0
2
0
6
Order By: Relevance
“…This leads to lower system performance at warmer ambient conditions and higher expansion losses, respectively. However, researchers are continuously improving refrigeration technology to overcome the lower system performance in warm and hot climates [3]. Figure 1a shows a typical CO 2 vapor compression cycle.…”
Section: Introductionmentioning
confidence: 99%
“…This leads to lower system performance at warmer ambient conditions and higher expansion losses, respectively. However, researchers are continuously improving refrigeration technology to overcome the lower system performance in warm and hot climates [3]. Figure 1a shows a typical CO 2 vapor compression cycle.…”
Section: Introductionmentioning
confidence: 99%
“…The energy performance improvement of both configurations facilitates utilisation in cold and moderate climate zones, and the R744 booster supermarket system with gas removal can achieve up to a 35% COP improvement [13]. However, the significant COP degradation of R744-based systems at transcritical conditions has forced an implementation of efficient devices and enhanced system configuration [14].…”
Section: Introductionmentioning
confidence: 99%
“…Se consideró que cada válvula de expansión es capaz de mantener un sobrecalentamiento constante en el evaporador de 10K, como suponen muchos autores (Gullo, 2019). Este sobrecalentamiento considera dos sobrecalentamientos: uno interno útil de 5K y otro de 5K en la línea de succión.…”
Section: Evaporadoresunclassified
“…Como asumen muchos autores (Gullo, 2019;Gullo et al, 2018bGullo et al, , 2017a, en los sistemas de refrigeración, la presión de condensación es controlada a temperaturas ambiente inferiores a 15 o 20°C para garantizar una diferencia de presión mínima a través de la válvula de expansión. Una diferencia de presión demasiado baja implica un menor flujo másico de refrigerante suministrado al evaporador, reduciéndose la demanda de refrigeración.…”
Section: Condensador Del Sistema Dxs-r404aunclassified
See 1 more Smart Citation