Integrated in‐syringe magnetic sheet solid‐phase extraction and dispersive liquid–liquid microextraction for determination of aflatoxins in fresh and moldy breads

Abstract: BACKGROUND: Magnetic three-dimensional graphene-based nanoadsorbents have unique characteristics such as large surface area, good thermal and chemical stability, and high adsorption capacity that make them efficient materials in sorbent-based extraction techniques. In this study, four aflatoxins (AFs) were analyzed in bread samples using magnetic three-dimensional graphene as the adsorbent phase in dispersive micro solid-phase extraction. RESULTS AND CONCLUSIONS: In-syringe magnetic sheet solid-phase extractio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…Sample preparation includes methods such as extraction, homogenization, pre‐concentration, the addition of internal standards, defatting and the clean‐up process 11 . The two‐step clean‐ups (combining both liquid extraction and magnetic solid‐phase extraction) have proven to be more efficient for removing interferences 12‐14 . An ideal procedure involves a pre‐liquid–liquid partition step proceeded by clean‐up with packed columns or dispersive solids.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Sample preparation includes methods such as extraction, homogenization, pre‐concentration, the addition of internal standards, defatting and the clean‐up process 11 . The two‐step clean‐ups (combining both liquid extraction and magnetic solid‐phase extraction) have proven to be more efficient for removing interferences 12‐14 . An ideal procedure involves a pre‐liquid–liquid partition step proceeded by clean‐up with packed columns or dispersive solids.…”
Section: Introductionmentioning
confidence: 99%
“…11 The two-step clean-ups (combining both liquid extraction and magnetic solid-phase extraction) have proven to be more efficient for removing interferences. [12][13][14] An ideal procedure involves a pre-liquid-liquid partition step proceeded by cleanup with packed columns or dispersive solids. The isolated analyte is then derivatized to further increase the sensitivity of the analytical method.…”
Section: Introductionmentioning