2023
DOI: 10.1016/j.micpath.2023.105985
|View full text |Cite
|
Sign up to set email alerts
|

Integration of metabolomics and transcriptomics analyses reveals sphingosine-1-phosphate-mediated S1PR2/PI3K/Akt pathway involved in Talaromyces marneffei infection of macrophages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 38 publications
0
2
0
Order By: Relevance
“…Subsequently, the supernatant was centrifuged again and transferred to the liner of the corresponding injection bottle for on-board analysis. The sample extracts were analyzed using a LC-ESI-MS/MS system (UPLC, ExionLC AD, https://sciex.com.cn/ ; MS, QTRAP® System, https://sciex.com/ ) [ 33 ]. LIT and triple quadrupole scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (QTRAP), QTRAP® LC-MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (Sciex) [ 33 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, the supernatant was centrifuged again and transferred to the liner of the corresponding injection bottle for on-board analysis. The sample extracts were analyzed using a LC-ESI-MS/MS system (UPLC, ExionLC AD, https://sciex.com.cn/ ; MS, QTRAP® System, https://sciex.com/ ) [ 33 ]. LIT and triple quadrupole scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (QTRAP), QTRAP® LC-MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (Sciex) [ 33 ].…”
Section: Methodsmentioning
confidence: 99%
“…The sample extracts were analyzed using a LC-ESI-MS/MS system (UPLC, ExionLC AD, https://sciex.com.cn/ ; MS, QTRAP® System, https://sciex.com/ ) [ 33 ]. LIT and triple quadrupole scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (QTRAP), QTRAP® LC-MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (Sciex) [ 33 ]. A specific set of MRM transitions were monitored for each period according to the metabolites eluted within this period.…”
Section: Methodsmentioning
confidence: 99%