2021
DOI: 10.1016/j.aca.2021.338449
|View full text |Cite
|
Sign up to set email alerts
|

Integration of microfluidic sample preparation with PCR detection to investigate the effects of simultaneous DNA-Inhibitor separation and DNA solution exchange

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 46 publications
0
6
0
Order By: Relevance
“…Utilizing this estimation, we designed high throughput particle washing devices, where the target microparticles were transferred from source water into a clean buffer with high efficiencies (490%). 20,49 Ducloue ´et al, 50 Yoon et al 51,52 and others [53][54][55][56] numerically investigated the effect of De number and fluid viscosity on the secondary vortices of shear-thinning fluids in curved microchannels. We experimentally studied the effects of channel geometry and fluid properties on the Dean velocity of shearthinning PEO in water solutions 57 and shear-thickening SiO 2 nanofluids 58 in curvilinear microchannels.…”
Section: Theorymentioning
confidence: 99%
See 3 more Smart Citations
“…Utilizing this estimation, we designed high throughput particle washing devices, where the target microparticles were transferred from source water into a clean buffer with high efficiencies (490%). 20,49 Ducloue ´et al, 50 Yoon et al 51,52 and others [53][54][55][56] numerically investigated the effect of De number and fluid viscosity on the secondary vortices of shear-thinning fluids in curved microchannels. We experimentally studied the effects of channel geometry and fluid properties on the Dean velocity of shearthinning PEO in water solutions 57 and shear-thickening SiO 2 nanofluids 58 in curvilinear microchannels.…”
Section: Theorymentioning
confidence: 99%
“…Utilizing this estimation, we designed high throughput particle washing devices, where the target microparticles were transferred from source water into a clean buffer with high efficiencies (>90%). 20,49…”
Section: Theorymentioning
confidence: 99%
See 2 more Smart Citations
“…Here, s represents the channel largest dimension (s = max (w,h), with w and h representing the channel width and height, respectively), and 𝜗 = 𝜇 𝜌 ⁄ is the fluid kinematic viscosity. Later on, this estimation of VDe was used to design a high throughput washing process in which microparticles were separated with high efficiencies (> 90%) and were transferred into a clean buffer (Bayat and Rezai, 2018;Nikdoost et al, 2021).…”
Section: Introductionmentioning
confidence: 99%