2021
DOI: 10.3390/mi12070762
|View full text |Cite
|
Sign up to set email alerts
|

Integration of Ultra-Low Volume Pneumatic Microfluidics with a Three-Dimensional Electrode Network for On-Chip Biochemical Sensing

Abstract: This paper reports a novel miniaturized pseudo reference electrode (RE) design for biasing Ion Sensitive Field Effect Transistors (ISFETs). It eliminates the need for post-CMOS processing and can scale up in numbers with the CMOS scaling. The presented design employs silane-mediated transfer of patterned gold electrode lines onto PDMS microfluidics such that the gold conformally coats the inside of microfluidic channel. Access to this electrode network is made possible by using “through-PDMS-vias” (TPV), which… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 36 publications
0
2
0
Order By: Relevance
“…Utilizing the physical phenomenon at the microscale, the time and energy efficiency of biochemical reactions could be greatly improved. The excellent compatibility of microfluidics in electromechanical control, medical science and biochemical reactions can also provide a significant possibility for minimizing reaction devices [3][4][5][6][7]. Following advances in techniques and the increase in demand, multiform microfluidic devices have been invented and adopted.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Utilizing the physical phenomenon at the microscale, the time and energy efficiency of biochemical reactions could be greatly improved. The excellent compatibility of microfluidics in electromechanical control, medical science and biochemical reactions can also provide a significant possibility for minimizing reaction devices [3][4][5][6][7]. Following advances in techniques and the increase in demand, multiform microfluidic devices have been invented and adopted.…”
Section: Introductionmentioning
confidence: 99%
“…For the spatially cycled protocol, the temperature at each area is fixed and the reaction solution flows through different temperature zones in turn. The solution could be driven by external pressure in a serpentine channel [7,18], a radial channel [33] or a spiral channel [25]; by integrated pneumatic micro pumps [8], ferro-fluidic plugs [34] or a magnetized ball pressing on a loop channel [35] with a rotating guiding magnet beneath; and by Rayleigh-Bénard convection in a cylindrical cavity [29]. For the temporally cycled protocol, the reaction solution is stationary while the temperature at the entire reaction zone changes over time.…”
Section: Introductionmentioning
confidence: 99%