2017 40th International Conference on Telecommunications and Signal Processing (TSP) 2017
DOI: 10.1109/tsp.2017.8075936
|View full text |Cite
|
Sign up to set email alerts
|

Intelligent radiant floor heating regulation system with wireless sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 5 publications
0
3
0
2
Order By: Relevance
“…This raises the question of how heating control usability is perceived, and how it may be improved, in the case of heating systems which are inherently slow-response, such as underfloor heating systems [58]. Despite these systems being suggested to generate energy savings and better heat distribution [59], [60], there is sparse research on user perceptions of underfloor heating systems and, in particular, whether slow response times pose a challenge. Recently, [61] found that underfloor heating systems were about as unfamiliar to users as heat pumps, with a lack of understanding of how they operate causing controllability issues.…”
Section: Literature Reviewmentioning
confidence: 99%
See 2 more Smart Citations
“…This raises the question of how heating control usability is perceived, and how it may be improved, in the case of heating systems which are inherently slow-response, such as underfloor heating systems [58]. Despite these systems being suggested to generate energy savings and better heat distribution [59], [60], there is sparse research on user perceptions of underfloor heating systems and, in particular, whether slow response times pose a challenge. Recently, [61] found that underfloor heating systems were about as unfamiliar to users as heat pumps, with a lack of understanding of how they operate causing controllability issues.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Two more studies found conflicting comments on the comfort provided by underfloor heating; in one, some respondents complained of excessive heat generated by the system [62] and in the other of insufficient heat [63]. [59] suggest that one shortcoming of underfloor heating systems is the low controllability, in particular the lack of differential temperature control in individual rooms. The sparse existing literature on underfloor heating systems shows that there is potential for expanding our understanding of heating system response to temperature adjustments, and how much of it can be solved by providing more accessible heating controls to residents.…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Поблизу поверхонь КА створюються значні застійні області, в яких практично відсутня швидкість руху повітря. У цих умовах коефіцієнти конвективної тепловіддачі з поверхні КА мають значення на рівні природної конвекції (3…5 Вт•м -2 К -1 ), і завдання стабілізації температури КА здійснюється за рахунок збільшення подачі термостатного повітря в відсік і теплознімання пристінними струменями [6,7]. У той же час поверхні вузлів КА, що знаходяться в зоні пристінних струменів, можуть піддаватися значному газодинамічному впливу термостатного повітря (V> 3-4 м/с).…”
unclassified
“…При зміні кута атаки або зміні швидкісного режиму при числах Маха М ≈ 1 можлива різка зміна надлишкового тиску на поверхні відділення КА. При відсутності лічильників води на вихідних люках СТС можливо втікання повітря з навколишнього середовища в відсік КА [2][3][4]6]. Перед відділенням КА від PH до моменту скидання головного обтічника за рахунок дренування повітря повинне бути забезпечене вирівнювання тиску в відсіку з тиском навколишнього простору.…”
unclassified