2014
DOI: 10.1186/1550-2783-11-s1-p46
|View full text |Cite
|
Sign up to set email alerts
|

Inter- and intra-day test-retest reliability of the Cosmed Fitmate ProTM indirect calorimeter for resting metabolic rate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…VCO 2 is not measured directly but estimated assuming a fixed respiratory quotient (RQ) of 0.85, which has been shown to introduce little error in RMR estimation (Nieman et al 2005; Nieman et al 2003). The Fitmate is portable, easy to use, and has been validated against the Douglas bag system (Nieman et al 2006), and it shows very high inter- and intra-day test-retest reliability for RMR measurement (Campbell et al 2014). …”
Section: Methodsmentioning
confidence: 99%
“…VCO 2 is not measured directly but estimated assuming a fixed respiratory quotient (RQ) of 0.85, which has been shown to introduce little error in RMR estimation (Nieman et al 2005; Nieman et al 2003). The Fitmate is portable, easy to use, and has been validated against the Douglas bag system (Nieman et al 2006), and it shows very high inter- and intra-day test-retest reliability for RMR measurement (Campbell et al 2014). …”
Section: Methodsmentioning
confidence: 99%
“…Relative consistency was accepted with the SEM and ICC values (0.981 and 0.946, responding during the day and in between). Moreover, no systematic error was found between measurements [17].…”
Section: Resting Energy Expenditure Assessment By Indirect Calorimetrymentioning
confidence: 81%
“…Estimation of REE (kcal/day) is possible thanks to the modified Weir equation: REE = [5.675 × VO2 + 1.593 × VCO2 − 21.7]; VO2 is the oxygen volume in the breath (mL/min) and VCO2 is the carbon dioxide output (mL/min) [16]. The Fitmate Med device was validated and showed very high reliability of the measurements obtained [17]. The results obtained using Fitmate Med are comparable to those obtained by the Douglas bag system, which uses a sensor to measure VCO2 [18].…”
Section: Resting Energy Expenditure Assessment By Indirect Calorimetrymentioning
confidence: 99%
“…Estimation of REE (kcal/d) is possible thanks to the modified Weir equation: REE = [5.675 × VO2 + 1.593 × VCO2 − 21.7], where VO2 is the oxygen volume in the breath (mL/min), and VCO 2 is the carbon dioxide output (mL/min) [24]. The Fitmate Med calorimeter was validated, and high reliability of the measurements was obtained [25]. The results obtained from the Fitmate Med device are comparable to the Douglas bag system, which uses a sensor to measure VCO2 [ [9].…”
Section: Resting Energy Expenditurementioning
confidence: 99%