2013
DOI: 10.1016/j.fas.2012.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Inter- and intra-observer reliability of a smartphone application for measuring hallux valgus angles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
18
0
8

Year Published

2013
2013
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(26 citation statements)
references
References 11 publications
0
18
0
8
Order By: Relevance
“…31,32 Ten orthopedic studies evaluated smartphone apps designed to measure joint angles and range of movement, either in real-time on live patients or from photographs or radiographic images of joints; these studies compared these novel methods with other well-established ''gold-standard'' techniques (see Table I). [20][21][22][23][24][25][26][27][28][29] Spinal, 24-26 shoulder, 27 elbow, 28 knee, [20][21][22][23] and metatarsophalangeal 29 joint angles were measured by apps using either the in-built smartphone accelerometer or a virtual in-app goniometer.…”
Section: Resultsmentioning
confidence: 99%
“…31,32 Ten orthopedic studies evaluated smartphone apps designed to measure joint angles and range of movement, either in real-time on live patients or from photographs or radiographic images of joints; these studies compared these novel methods with other well-established ''gold-standard'' techniques (see Table I). [20][21][22][23][24][25][26][27][28][29] Spinal, 24-26 shoulder, 27 elbow, 28 knee, [20][21][22][23] and metatarsophalangeal 29 joint angles were measured by apps using either the in-built smartphone accelerometer or a virtual in-app goniometer.…”
Section: Resultsmentioning
confidence: 99%
“…Mobile phone apps are being validated as goniometric tools [23] through clinometers [24] or goniometers [25]. Image-based apps have been created for measuring elbow and hallux valgus angles [26,27], and clinometer-based apps have also been created for measuring shoulder ROM [24]. In addition, an inclinometer-based app on a mobile phone has been demonstrated to have an acceptable reliability compared to conventional inclinometers that evaluate the shoulder joint [28].…”
Section: Introductionmentioning
confidence: 99%
“…. En casos de aumento del PASA, una osteotomía proximal empeorará el problema118 , lo que se puede solucionar añadiendo una osteotomía distal para rotar la cabeza metatarsal medialmente20,64,87,116 . tenotomía del tendón adductor del hallux y artrolisis lateral, 3.--osteotomía de F1 para varización de la misma, 4.--vendaje corrector, capital para mantener las correcciones óseas49,72,127,153 .…”
unclassified
“…,179 y con mediciones digitalizadas167 . La medición del AHV y del IAM es fiable incluso con aplicaciones para móviles, aunque el uso de las herramientas PACS son un método superior116 . La medición de otros ángulos, como el DMAA o el talometatarsal ha mostrado una alta variabilidad inter e intraobservador18,116,123,204 .…”
unclassified
See 1 more Smart Citation