2016 17th International Conference on Harmonics and Quality of Power (ICHQP) 2016
DOI: 10.1109/ichqp.2016.7783479
|View full text |Cite
|
Sign up to set email alerts
|

Interaction between grid-connected PV systems and LED lamps: Directions for further research on harmonics and supraharmonics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 13 publications
0
10
0
1
Order By: Relevance
“…As a result, a decrease in the power quality of power distribution as a large number of LED lamps are usually connected to the same bus, resulting in high current harmonic distortion fed into the power system. For this reason, the power quality resulting from using LED lamps in power distribution systems needs to be studied and analyzed [38][39][40][41][42][43][44][45]. In Molina et al's work [38], a frequency-domain low-watt LED lamp model for current harmonic distortion calculation, which is applied for large-scale harmonic penetration, is discussed.…”
Section: Literature Reviewmentioning
confidence: 99%
“…As a result, a decrease in the power quality of power distribution as a large number of LED lamps are usually connected to the same bus, resulting in high current harmonic distortion fed into the power system. For this reason, the power quality resulting from using LED lamps in power distribution systems needs to be studied and analyzed [38][39][40][41][42][43][44][45]. In Molina et al's work [38], a frequency-domain low-watt LED lamp model for current harmonic distortion calculation, which is applied for large-scale harmonic penetration, is discussed.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The use of such light sources is also economically advantageous-the long life means lower investment costs, and the low active power consumption translates into lower operational costs. Despite many advantages, the electroluminescent light sources have one major drawback-they cause strong distortions in the current [13][14][15][16][17][18][19][20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…If the number of LED lamps connected to electrical systems constitutes a significant part of all of the electrical light sources in a facility, then, because of the level of power consumed, problems with the impact of higher harmonics in such mains occur. In many scientific centres from all over the world, research related to the quality of the electricity in the power systems of LED lamps is conducted [13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32]. At the same time, different solutions aimed at the improvement of the electricity quality parameters in these systems are proposed [33][34][35][36][37][38][39][40][41][42][43][44][45][46].…”
mentioning
confidence: 99%
“…apresentam resultados de medição de 1 até 48 CFLs em uma instalação elétrica. Estudos preliminares envolvendo o uso de lâmpadas LED porBusatto et al (2016) mostram que a emissão de supraharmônicas são maiores que CFL, embora os possíveis efeitos adversos não estejam claros Sakar et al (2019). apresentam uma metodologia para verificação da influência das emissões secundárias em lâmpadas LED individualmente.3.3 Emissão devido a Conversores Eletrônicos de PotênciaCEPs são fontes de supraharmônicas, uma vez que sintetizam corrente através de comutações na faixa de kHz.…”
unclassified