2002
DOI: 10.1002/jmri.10123
|View full text |Cite
|
Sign up to set email alerts
|

Interactive body magnetic resonance fluoroscopy using modified single‐shot half‐Fourier rapid acquisition with relaxation enhancement (RARE) with multiparameter control

Abstract: Purpose: To develop a technique for interactive fluoroscopic abdominal magnetic resonance imaging (MRI) based on a single-shot half-Fourier rapid acquisition and relaxation-enhanced sequence. Materials and Methods:The sequence was modified by incorporating inner-volume excitation, driven-equilibrium signal enhancement, and reduced flip angle refocusing pulses. Contrast control was provided by integrating "onthe-fly" selection of phase encoding view order, fat suppression, and section thickness. The resulting s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2006
2006
2011
2011

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 17 publications
0
16
0
Order By: Relevance
“…The RACE method was developed from a separate gradient-echo-based sequence and integrated into an interactive 2D SSFSE sequence [11]. This allowed for on-the-fly sequence switching [12] (switching time ≈95 ms) between SSFSE and RACE [13].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The RACE method was developed from a separate gradient-echo-based sequence and integrated into an interactive 2D SSFSE sequence [11]. This allowed for on-the-fly sequence switching [12] (switching time ≈95 ms) between SSFSE and RACE [13].…”
Section: Methodsmentioning
confidence: 99%
“…We propose that a 2D projection FBI technique could be used to allow interactive angiography for targeted and repeated imaging of a specific vessel. We further propose that, based on recent developments in interactive 2D SSFSE sequences [10,11], the technique could be integrated into an existing, commercially available, interactive imaging tool. An interactive 2D unenhanced MRA technique could be useful as a vascular localiser, as a method of establishing vessel patency in a multi-contrast fluoroscopic examination [12], or for realtime monitoring of interventional vascular procedures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As proposed in Ref. 4, this sequence was combined with a LoLo (5) or inner volume imaging (5) preparation whereby the initial 90°RF pulse is applied to a slice perpendicular to the subsequent 180°refocusing pulses (Fig. 1).…”
Section: Targeted-haste Pulse Sequencementioning
confidence: 99%
“…We previously reported our work on integrating a modified single-shot half-Fourier RARE sequence into a proprietary interactive imaging environment (i/Drive Pro; GE Healthcare Technologies, Milwaukee, WI, USA) (3). The system provides for interactive control of imaging geometry, including the field of view (FOV), slice position and thickness, and contrast (e.g., TE eff , TR, and fat suppression).…”
Section: Magnetic Resonance Cholangiography (Mrc)mentioning
confidence: 99%