2000
DOI: 10.1016/s0265-931x(00)00045-x
|View full text |Cite
|
Sign up to set email alerts
|

Intercomparison of activity size distribution of thoron progeny and a mixture of radon and thoron progeny

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 38 publications
0
7
0
1
Order By: Relevance
“…This is in agreement with what is measured for indoor and mining environments, where the unattached 212 Pb was found to have particle sizes of approximately 1 nm (Chen et al., 1997). Measurements carried out in a radon test chamber, as part of an intercomparison exercise, also showed median diameters less than 1 nm for unattached 212 Pb (Cheng et al., 2000).…”
Section: Annex a Aerosol Data And Dose Coefficients For Radon Progenymentioning
confidence: 95%
“…This is in agreement with what is measured for indoor and mining environments, where the unattached 212 Pb was found to have particle sizes of approximately 1 nm (Chen et al., 1997). Measurements carried out in a radon test chamber, as part of an intercomparison exercise, also showed median diameters less than 1 nm for unattached 212 Pb (Cheng et al., 2000).…”
Section: Annex a Aerosol Data And Dose Coefficients For Radon Progenymentioning
confidence: 95%
“…In addition, RnDP appeared in the nucleation mode (attached to particles of 14-40 nm), the accumulation mode (210-310 nm), and the coarse mode (3000-5000 nm) (Porstendörfer, 2001). In an intercomparison experiment carried out in a test chamber, the AMD values of the unattached RnDP were found in the range from 0.53 to 1.76 nm, followed by a gap until about 50 nm when the attached RnDP appeared (Cheng et al, 2000). As reviewed by , f un differs substantially from place to place and, depending on the environmental conditions, its value range from 0.006 to 0.83.…”
Section: Size Distribution Of Radon Short-lived Decay Productsmentioning
confidence: 97%
“…In addition, RnDP appeared in the nucleation (attached to particles of 14–40 nm), accumulation (210–310 nm), and coarse modes (3000–5000 nm) [ 32 ]. In an intercomparison experiment carried out in a test chamber, the AMD values of the unattached RnDP were found in the range from 0.53 to 1.76 nm, followed by a gap until about 50 nm when the attached RnDP appeared [ 34 ].…”
Section: Introductionmentioning
confidence: 99%