2020
DOI: 10.1109/tpel.2020.2986695
|View full text |Cite
|
Sign up to set email alerts
|

Interconnected Autonomous ac Microgrids via Back-to-Back Converters—Part II: Stability Analysis

Abstract:  Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commercial gain  You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
4

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(18 citation statements)
references
References 43 publications
0
18
0
Order By: Relevance
“…In the existing refs. [30][31][32][33][34], voltage recovery and current sharing have not been considered. In order to solve this problem, voltage recovery and current sharing control are proposed based on the voltage and current information provided by the upper PMS.…”
Section: Current Sharing and Voltage Recovery Controlmentioning
confidence: 99%
“…In the existing refs. [30][31][32][33][34], voltage recovery and current sharing have not been considered. In order to solve this problem, voltage recovery and current sharing control are proposed based on the voltage and current information provided by the upper PMS.…”
Section: Current Sharing and Voltage Recovery Controlmentioning
confidence: 99%
“…Generally, the dynamics of three MG frequencies are similar due to interlinking using circuit breakers, i.e. the power section of IMGs is uniformed unlike interconnection using back-to-back converters [4], [5], [29]. Moreover, the frequency oscillations can be seen, which are caused by the inter-MG modes.…”
Section: B Frequency Responsementioning
confidence: 99%
“…The AC MGs can be interconnected via circuit breakers [6], [20], [21], [28], static switches [3] or back-to-back converters [4], [5], [29]. The first case is often of interest since it is economic.…”
mentioning
confidence: 99%
“…In addition, microgrids safeguard electricity in unconnected remote regions [9]. The main grid recognizes the microgrid as a single entity and stabilizes its voltage level when grid-connected; therefore, its control requirement is to deliver power to the main grids [10].…”
Section: Introductionmentioning
confidence: 99%