2020
DOI: 10.1016/j.thromres.2020.04.044
|View full text |Cite
|
Sign up to set email alerts
|

Interference of DOAC stop and DOAC remove in the thrombin generation assay and coagulation assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
25
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(28 citation statements)
references
References 11 publications
3
25
0
Order By: Relevance
“…Previously, Kopatz et al showed a complete normalization of the CAT traces up to DOACs concentration 80 ng/ml; 7 however, DOAC-Stop ® has never been assessed on the TEG before. CAT results from NPP/ WPP suggested hypercoagulability, as previously reported, 7,9 whereas TEG results suggested hypocoagulability. Factor assays results showed a reduction of factors involved in the intrinsic coagulation pathway, suggesting that DOAC-Stop ® might be activating coagulation through the contact activation pathway, with consumption of these factors.…”
Section: The Effect Of Doac-stop ® On Several Oral and Parenteral Anticoagulantssupporting
confidence: 81%
“…Previously, Kopatz et al showed a complete normalization of the CAT traces up to DOACs concentration 80 ng/ml; 7 however, DOAC-Stop ® has never been assessed on the TEG before. CAT results from NPP/ WPP suggested hypercoagulability, as previously reported, 7,9 whereas TEG results suggested hypocoagulability. Factor assays results showed a reduction of factors involved in the intrinsic coagulation pathway, suggesting that DOAC-Stop ® might be activating coagulation through the contact activation pathway, with consumption of these factors.…”
Section: The Effect Of Doac-stop ® On Several Oral and Parenteral Anticoagulantssupporting
confidence: 81%
“…This procoagulant effect seems to be related to slight reduction in tissue factor pathway inhibitor (TFPI). 50,51 The elimination of DOAC presence in plasma using filters like the DP-Filter (5-Diagnostics) or the DOAC-Filter (Diagnostica Stago, France) showed promising results. 39,52 However, potential unintended filtration of coagulation proteins seen with other filtering mechanisms (e.g., von Willebrand factor) may occur, but the interference of DOAC-Stop or DOAC-Remove on these other coagulation proteins has also been found (e.g., interference on TFPI), impacting mainly TGA.…”
Section: Interference Of Doac On Coagulation Assaysmentioning
confidence: 99%
“…Because of the increased necessity of testing patients for LA while on DOAC, several publications have emerged that have suggested the use of an insoluble adsorbent material to eliminate DOACs in vitro. 68,[70][71][72] This DOAC-Stop reagent can be added to samples before testing, and it will not affect screening tests like dRVVT in patients not receiving DOACs. Another potential way to overcome and eliminate the interfering effect of DOACs would be to use a simple charcoal product.…”
Section: Evaluating La Results In Anticoagulated Patientsmentioning
confidence: 99%