International descriptive and interventional survey for oxycholesterol determination by gas- and liquid-chromatographic methods

Abstract: Increasing numbers of laboratories develop new methods based on gas-liquid and high-performance liquid chromatography to determine serum concentrations of oxygenated cholesterol metabolites such as 7α-, 24(S)-, and 27-hydroxycholesterol. We initiated a first international descriptive oxycholesterol (OCS) survey in 2013 and a second interventional survey 2014 in order to compare levels of OCS reported by different laboratories and to define possible sources of analytical errors. In 2013 a set of two lyophilized… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 25 publications
0
14
0
Order By: Relevance
“…To a screw-capped vial sealed with a Teflon septum, 1 ml of milk or colostrum, 1ml of a 100 mg/mL distilled water suspended Table S1) using standard curves for the listed sterols. 32,33,34,35 Replicated analysis of 1 mL of whole-milk, standardized, pasteurized at standard parameters (n = 12) resulted in an interassay CV as 3.87% for 7βOHC, 3.97% for 7KC and 3.13% for 27OHC, respectively. Whole milk pasteurized at standard temperature was added with 25 ng of 7βOHC, 7KC and 27OHC, and analyzed as previously described (n = 3 independent experiments).…”
Section: Cholesterol and Oxysterols Determinationmentioning
confidence: 99%
“…To a screw-capped vial sealed with a Teflon septum, 1 ml of milk or colostrum, 1ml of a 100 mg/mL distilled water suspended Table S1) using standard curves for the listed sterols. 32,33,34,35 Replicated analysis of 1 mL of whole-milk, standardized, pasteurized at standard parameters (n = 12) resulted in an interassay CV as 3.87% for 7βOHC, 3.97% for 7KC and 3.13% for 27OHC, respectively. Whole milk pasteurized at standard temperature was added with 25 ng of 7βOHC, 7KC and 27OHC, and analyzed as previously described (n = 3 independent experiments).…”
Section: Cholesterol and Oxysterols Determinationmentioning
confidence: 99%
“…A lipidomic study has been performed in which many different laboratories analysed the NIST SRM 1950 plasma sample using different MS methods [14] and further studies are planned targeting on specific lipid groups. Similar studies have already been performed with locally prepared plasma samples distributed to collaborating groups for sterol and oxysterol analysis [39,40]. While these "ring" trials will not necessarily lead to "true" quantitative values, they will lead to "consensus" values which are very important when comparing data sets from different laboratories.…”
Section: Quantificationmentioning
confidence: 86%
“…For example, in 2014 eleven laboratories measured the “total” 24S-HC content of two serum samples by MS methods, the mean ± standard deviation values for the two samples were 60.9 ± 36.7 ng/mL and 38.0 ± 21.6 ng/mL. The median values with the 16%–84% range given in brackets were 57.0 (38.5–78.9) ng/mL and 33.0 (23.7–48.6) ng/mL [17]. Although, most values clustered about the median, work still needs to be done to harmonise analytical methods.…”
Section: Experimentationmentioning