2022
DOI: 10.1142/s0219265921450079
|View full text |Cite
|
Sign up to set email alerts
|

Internet of Things-Based Risk Warning System for Distribution Grid Operation State

Abstract: The distribution network is the most terminal part of the power system. The safety and stability of its operation directly affect the power supply reliability of the power system. The operation status of the equipment has always been the focus of researchers. Once a problem occurs in the operation of the distribution network, it will have a significant impact on public safety and social development. Therefore, real-time monitoring of the operation status of the distribution network is very important. In order … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…In the risk warning network established in this paper, if the consistency index is ≥ 0.95, it is determined as strong consistency in risk warning data mining; If the consistency index is ≤ 0.85, it is determined as weak consistency in risk warning data mining. Under other conditions that are consistent, after using the methods of reference [2] and reference [3], the consistency index of risk warning data changes in the range of 0.836 to 0.902, indicating weak consistency in risk warning data mining. After using the method proposed in this paper, the consistency index of risk warning data varies between 0.999 and 1.000, indicating strong consistency in risk warning data mining.…”
Section: Accuracy Results Of Risk Detection For Power Grid Equipment ...mentioning
confidence: 99%
See 1 more Smart Citation
“…In the risk warning network established in this paper, if the consistency index is ≥ 0.95, it is determined as strong consistency in risk warning data mining; If the consistency index is ≤ 0.85, it is determined as weak consistency in risk warning data mining. Under other conditions that are consistent, after using the methods of reference [2] and reference [3], the consistency index of risk warning data changes in the range of 0.836 to 0.902, indicating weak consistency in risk warning data mining. After using the method proposed in this paper, the consistency index of risk warning data varies between 0.999 and 1.000, indicating strong consistency in risk warning data mining.…”
Section: Accuracy Results Of Risk Detection For Power Grid Equipment ...mentioning
confidence: 99%
“…Based on the fault rate curve and Weibull distribution function of the power grid fault rate model, establish a fault risk analysis model for the power grid communication link, and complete the fault risk assessment of the power grid communication link. Reference [3] proposes a distribution network operation status risk warning system based on the Internet of Things. Analyzed the weights of risk indicators, determined the detection indicators of the risk warning system, and established a risk warning evaluation model by analyzing the risk warning indicator system of the operation status of the distribution network.…”
Section: Introductionmentioning
confidence: 99%