2010
DOI: 10.1177/145749691009900107
|View full text |Cite
|
Sign up to set email alerts
|

Intra-Supra Annular Aortic Valve and Complete Supra Annular Aortic Valve: A Literature Review and Hemodynamic Comparison

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
4
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 17 publications
0
4
0
2
Order By: Relevance
“…This is in accordance with the adequate sizing of the effective orifice area criteria so that residual stenosis after valve implantation can be avoided, thereby minimizing the occurrence of elevated pressure gradients through the valve [ 19 ] . On the other hand, the occurrence of unsatisfactory pressure gradient across the prosthesis should also be avoided, as it would result in an incomplete reduction of the left ventricular hypertrophy [ 20 , 21 ] . Manufacturers have developed models of valves for different sutures without addressing controversies about the proper diameter of the prosthesis according to the patient's aortic annulus [ 19 , 20 ] and relying on the experience of clinical practice favoring hemodynamic performance.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This is in accordance with the adequate sizing of the effective orifice area criteria so that residual stenosis after valve implantation can be avoided, thereby minimizing the occurrence of elevated pressure gradients through the valve [ 19 ] . On the other hand, the occurrence of unsatisfactory pressure gradient across the prosthesis should also be avoided, as it would result in an incomplete reduction of the left ventricular hypertrophy [ 20 , 21 ] . Manufacturers have developed models of valves for different sutures without addressing controversies about the proper diameter of the prosthesis according to the patient's aortic annulus [ 19 , 20 ] and relying on the experience of clinical practice favoring hemodynamic performance.…”
Section: Discussionmentioning
confidence: 99%
“…The AGN 21 - 751 (Regent TM ) model is designed for supra-annular suture and the AJ 21 - 501 (Masters Series) model for intra-annular suture. Currently, due to hemodynamic advantages, most surgeons employ the supra-annular positioning, even if there is a discrepancy among manufacturers regarding different internal diameter of the prostheses based on valves with the same nominal diameter [ 20 - 22 ] . For the prostheses studied here, which are from the same manufacturer, the choice of supra-annular prosthesis implies a valve with a larger inner diameter, although the two models have the same nominal diameter (21 mm).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Суть операции Озаки заключается в следующем: замене трех натив ных аортальных створок аутологичным пе рикардом, обработанным глутаральдегидом. Одно из преимуществ этого метода -удовле творительные градиенты на клапане при од новременном обеспечении более эффектив ной площади отверстия клапана [5]. Однако этот метод требует большого перикардиаль ного лоскута размером не менее 7×8 см, что обычно влечет за собой необходимость пол ной стернотомии для выделения.…”
Section: Introductionunclassified
“…Стремление к оптимизации показателей гемодинамики привело к созданию проте зов, предназначенных для супрааннулярной (надкольцевой) их установки. Супраанну лярные протезы были сконструированы для размещения опорного кольца протеза над фиброзным кольцом клапана, тем самым увеличивая эффективную площадь отверстия и облегчая торможение обратного кровото ка [4]. В одном исследовании сообщалось, что матрацный шов в сочетании с супраан нулярным позиционированием протеза обеспечивают превосходную гемодинамику [5].…”
Section: Introductionunclassified