2020
DOI: 10.5397/cise.2020.00213
|View full text |Cite
|
Sign up to set email alerts
|

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

Abstract: Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…If there is looseness, revision with a longer stem by using a plate and/or bone graft is recommended [ 3 ]. There are some reports recommending revision using strut bone allograft and internal fixation using a plate or cable system when the bone is fragile due to loosening [ 4 , 5 , 6 ]. In this case, as well, we examined options including osteosynthesis using bone grafts such as autograft and allograft.…”
Section: Discussionmentioning
confidence: 99%
“…If there is looseness, revision with a longer stem by using a plate and/or bone graft is recommended [ 3 ]. There are some reports recommending revision using strut bone allograft and internal fixation using a plate or cable system when the bone is fragile due to loosening [ 4 , 5 , 6 ]. In this case, as well, we examined options including osteosynthesis using bone grafts such as autograft and allograft.…”
Section: Discussionmentioning
confidence: 99%
“…Left lateral table supports were applied to the radiolucent operating table to enable the tilting of the table. and knee revision arthroplasty procedures, peri-prosthetic fractures, avascular necrosis, tumour surgery, non-union of fractures and in spine surgery [6][7][8][9][10][11][12]. However, the use of strut grafts for a hybrid plate/structural allograft construct (PAC) for primary or failed internal fixation of long bone fractures in elderly patients with osteoporosis hasn't really been explored.…”
Section: Therapeutic Interventionmentioning
confidence: 99%