2022
DOI: 10.1080/02713683.2022.2061004
|View full text |Cite
|
Sign up to set email alerts
|

Intrasession Repeatability and Intersession Reproducibility of Macular Vessel Parameters on Optical Coherence Tomography Angiography in Glaucomatous and Non-Glaucomatous Eyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 35 publications
0
3
0
Order By: Relevance
“…It would be useful to investigate the repeatability and reproducibility of our device and software in control subjects to determine whether a difference in OCTA parameter measurements in a given patient is clinically significant or within the accepted “noise” of the technology and the patient’s daily physiological variation. Studies have shown good intra-session repeatability and good inter-session reproducibility of OCTA vessel parameter measurements in healthy and glaucomatous eyes using commercial software for OCTA devices [ 43 , 44 , 45 , 46 ]. The inter-session coefficient of repeatability is the best measure for this assessment as it represents the estimated range in which the difference between two repeated measurements for a given eye falls 95% of the time [ 43 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It would be useful to investigate the repeatability and reproducibility of our device and software in control subjects to determine whether a difference in OCTA parameter measurements in a given patient is clinically significant or within the accepted “noise” of the technology and the patient’s daily physiological variation. Studies have shown good intra-session repeatability and good inter-session reproducibility of OCTA vessel parameter measurements in healthy and glaucomatous eyes using commercial software for OCTA devices [ 43 , 44 , 45 , 46 ]. The inter-session coefficient of repeatability is the best measure for this assessment as it represents the estimated range in which the difference between two repeated measurements for a given eye falls 95% of the time [ 43 ].…”
Section: Discussionmentioning
confidence: 99%
“…The inter-session coefficient of repeatability is the best measure for this assessment as it represents the estimated range in which the difference between two repeated measurements for a given eye falls 95% of the time [ 43 ]. Vorperian et al [ 46 ], using commercial software for macular VD parameters, reported the inter-session within-eye coefficient of repeatability of 1.349 (95% CI 1.173; 1.528) for non-glaucomatous eyes and 1.767 (95% CI 1.501; 2.029) for glaucomatous eyes. This means that the absolute difference between two measurements and between two sessions should not be greater than 1.349 for non-glaucomatous and 1.767 for glaucomatous eyes in 95% of cases [ 46 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation