2021
DOI: 10.1016/j.ejmp.2021.02.019
|View full text |Cite
|
Sign up to set email alerts
|

Inverse planning in Gamma Knife radiosurgery: A comparative planning study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
17
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(21 citation statements)
references
References 25 publications
3
17
1
Order By: Relevance
“…Wieczorek et al ( 11) compared inverse plans optimized by GK Lightning with manual forward plans on 115 lesions and demonstrated that the inverse plans were comparable or superior to forward plans with regard to plan quality metrics. Spaniol et al (12) performed similar analyses on 38 patients' plans, as well as evaluated inter-operator variability on one plan for every pathology type. They also showed improved plan quality with GK Lightning, with minimal variability on the operator's experience.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Wieczorek et al ( 11) compared inverse plans optimized by GK Lightning with manual forward plans on 115 lesions and demonstrated that the inverse plans were comparable or superior to forward plans with regard to plan quality metrics. Spaniol et al (12) performed similar analyses on 38 patients' plans, as well as evaluated inter-operator variability on one plan for every pathology type. They also showed improved plan quality with GK Lightning, with minimal variability on the operator's experience.…”
Section: Discussionmentioning
confidence: 99%
“…Spaniol et al. ( 12 ) performed similar analyses on 38 patients’ plans, as well as evaluated inter-operator variability on one plan for every pathology type. They also showed improved plan quality with GK Lightning, with minimal variability on the operator’s experience.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The GammaPlan Lightning optimization system was used to create treatment plans using the same margin dose (20 Gy) to the target as in the actual clinical plan. 16 Parameters for Lightning optimization were identical for all plans (low-dose weight = 0.50; beam-on-time weight = 0.50; max dose = 40 Gy, coverage = 100%, max dose to risk structure = 14 Gy). A baseline treatment plan without considering any connectome networks was created and compared with subsequent plans considering a single network as an avoidance structure.…”
Section: Clinical Presentationmentioning
confidence: 99%
“…4 With the advent of the Icon platform, stereotactic radiotherapy (SRT) with treatment in three or more fractions has now become feasible on the GK unit. 5,6 Like the Per-fexion™, the Icon houses 192 sealed cobalt-60 sources arranged in eight motorized sectors, each containing 24 sources. 4,7 Each sector is controlled independently and can be in one of four collimator states: 4, 8, 16 mm, or beam-off (block) state.…”
Section: Introductionmentioning
confidence: 99%