2021
DOI: 10.1007/s00214-021-02816-y
|View full text |Cite
|
Sign up to set email alerts
|

Investigating an efficient and accurate protocol for sampling structures from molecular dynamics simulations: a close look by different wavelet families

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 53 publications
0
3
0
Order By: Relevance
“…For compounds containing transition metals, the most suitable wavelet is bior1.3. 35 Figure 3a shows the original signal (blue signal) and the signal treated with the bior 1.3 wavelet (red signal), figure 3b shows only the treated signal. Analyzing the signals in Figure 2, it is possible to observe that each step of the signal corresponds to a conformation (interaction calls as can be seen in the X axis legend of Figure 2), in real numbers the number of initial structures was 6000 and the number of treated structures was 100, thus; it is noted that the number of treated structures (number of steps of the red signal) are much smaller than the number of initial structures (number of steps of the blue signal), this signal compression and consequently the number of conformations is very important for further calculations to be performed.…”
Section: Selection Of Structures From Molecular Dynamics Simulationsmentioning
confidence: 99%
“…For compounds containing transition metals, the most suitable wavelet is bior1.3. 35 Figure 3a shows the original signal (blue signal) and the signal treated with the bior 1.3 wavelet (red signal), figure 3b shows only the treated signal. Analyzing the signals in Figure 2, it is possible to observe that each step of the signal corresponds to a conformation (interaction calls as can be seen in the X axis legend of Figure 2), in real numbers the number of initial structures was 6000 and the number of treated structures was 100, thus; it is noted that the number of treated structures (number of steps of the red signal) are much smaller than the number of initial structures (number of steps of the blue signal), this signal compression and consequently the number of conformations is very important for further calculations to be performed.…”
Section: Selection Of Structures From Molecular Dynamics Simulationsmentioning
confidence: 99%
“…In this line, in the current work, we have employed the wavelet bior 1.3 to select the main conformations obtained by molecular dynamics calculations. Wavelet bior 1.3 is used successfully for the selection of MD configurations for coordination compounds containing transition metals [28].…”
Section: 2-molecular Quantum Simulations Structure Selection (Owsca) ...mentioning
confidence: 99%
“…In addition to simultaneous quantitative determination of a multi-component mixtures [36,37], CWT has been used for periodic error compensation [38], electrochemical signals [39], spectrophotometric determination of drugs using high performance liquid chromatography [40], solvent effect on MRI probe and [41] sampling structures from molecular dynamics simulations [42]. This approach has the advantages of removing the Fourier transform restriction, increasing the signal-to-noise ratio in comparison to previous approaches, and reducing spectral interference.…”
Section: Introductionmentioning
confidence: 99%