2005
DOI: 10.1263/jbb.100.131
|View full text |Cite
|
Sign up to set email alerts
|

Investigating neuronal activity with planar microelectrode arrays: achievements and new perspectives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
114
0
2

Year Published

2010
2010
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 134 publications
(116 citation statements)
references
References 110 publications
0
114
0
2
Order By: Relevance
“…Mapping LTD in a cortical circuit MEA technology represents a valuable tool to record responses in numerous sites simultaneously for a long time (Oka et al, 1999;Morin et al, 2005;Hofmann and Bading, 2006). We have used a 64-channel MEA system, MED64, in mouse brain slices to study the spatial distribution of synaptic transmission and LTD in the ACC.…”
Section: Discussionmentioning
confidence: 99%
“…Mapping LTD in a cortical circuit MEA technology represents a valuable tool to record responses in numerous sites simultaneously for a long time (Oka et al, 1999;Morin et al, 2005;Hofmann and Bading, 2006). We have used a 64-channel MEA system, MED64, in mouse brain slices to study the spatial distribution of synaptic transmission and LTD in the ACC.…”
Section: Discussionmentioning
confidence: 99%
“…These two commerciallyavailable MEA systems make possible the wide use of the technique on various biological preparations, including acutely-dissociated brain slices (e.g., hippocampus, cortex, hypothalamus, substantia nigra, amygdala, superior colliculus, and brain stem), cultured slices (e.g., hippocampus, spinal cord, suprachiasmatic nucleus, cerebellum, and septohippocampal co-culture), retina, myocardial (ventricular and atrial slices) and smooth muscle from mammals [2,[17][18][19][20][21][22] .…”
Section: Stable Field Excitatory Postsynaptic Potentials (Fepsps)mentioning
confidence: 99%
“…testing and behavioral studies [2,20] . Compared to traditional electrophysiology, the MEA technique is superior in that it enables: (1) gathering large amounts of spatial information on the internal dynamics of networks with multisite recordings [42,43] ; (2) long-term analysis of the spatiotemporal distribution of network-level electrical activity [20,44] ; (3) multisite stimulation and recording within one slice [20,42] ;…”
Section: Examples Of Ltd Recording Using Meas Besidesmentioning
confidence: 99%
“…It was shown that microfluidic-based systems have a great potential in application for single-cell analysis [1,2] and instant analyses or so called point-of-care (POC) diagnostics [3][4][5]. In this respect, microfluidics systems provide conditions that are comparable to in vivo conditions [1].…”
Section: Introductionmentioning
confidence: 99%
“…Fast evaporation of fluid (e.g., biological media, chemical reagents) in the microchannels may cause premature cell death especially in long-term culture assays [5]. To reduce the risk of culture medium evaporation, encapsulation of microchannels is considered an essential requirement.…”
Section: Introductionmentioning
confidence: 99%