2020
DOI: 10.1016/j.ijrefrig.2020.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the performance of novel green solvents in absorption refrigeration cycles: Energy and exergy analyses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 31 publications
(17 citation statements)
references
References 31 publications
0
17
0
Order By: Relevance
“…Haghbakhsh et al 67 primarily applied DESs in absorption refrigeration as a potential working medium to investigate the feasibility of DESs in refrigeration cycles, where thermodynamic models consisting of the Non Random Two Liquid (NRTL) equation and the Soave−Redlich−Kwong (SRK) EOS were used to correlate the experimental result. The modified SRK-NRTL model is proved to fit well with the obtained experimental data of reline, ethaline, and glyceline.…”
Section: Synthesized and Thoroughly Studied 1-ethylimidazolium Ethyl ...mentioning
confidence: 99%
“…Haghbakhsh et al 67 primarily applied DESs in absorption refrigeration as a potential working medium to investigate the feasibility of DESs in refrigeration cycles, where thermodynamic models consisting of the Non Random Two Liquid (NRTL) equation and the Soave−Redlich−Kwong (SRK) EOS were used to correlate the experimental result. The modified SRK-NRTL model is proved to fit well with the obtained experimental data of reline, ethaline, and glyceline.…”
Section: Synthesized and Thoroughly Studied 1-ethylimidazolium Ethyl ...mentioning
confidence: 99%
“…Studies in the literature on absorption refrigeration cycles have determined that the work done by the pump is negligible in comparison to the amount of heat transfer in the regenerator [ 7 , 9 , 10 , 60 ]. Accordingly, the work done by the pump, W p , was neglected in this work.…”
Section: Resultsmentioning
confidence: 99%
“…Accordingly, the work done by the pump, W p , was neglected in this work. However, to make sure that this is indeed a valid assumption, the work done for pumping all three DES/water working pairs was calculated using Equation (32) [ 60 ]. where V is the volumetric flow rate of the solution, and η p is the efficiency of the pump.…”
Section: Resultsmentioning
confidence: 99%
“…The E eva is calculated by the evaporation heat(P eva ), the evaporation temperature(T eva =T 6 ), and the environment temperature(T 0 =24.5℃). While the E gen is calculated by the generation heat(P gen ), the generation temperature(T gen =T 1 ), and the environment temperature(T 0 =24.5℃) [25].…”
Section: Calculation Methods Of Exergy Coefficient Of Performance (Ecop)mentioning
confidence: 99%