1982
DOI: 10.1109/mper.1982.5520976
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on Test Method of DC XLPE Cable

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
1
1
0
Order By: Relevance
“…The obtained n values from the results of the four test groups all lie in the range of 13 to 16, which is consistent with the existing reference range of n values from 9 to 20 [21]. The values of I min for all groups do not exceed 5%, meeting the constraint of using λ max /3 as the Dc value.…”
Section: Tests and Data Validationsupporting
confidence: 86%
See 1 more Smart Citation
“…The obtained n values from the results of the four test groups all lie in the range of 13 to 16, which is consistent with the existing reference range of n values from 9 to 20 [21]. The values of I min for all groups do not exceed 5%, meeting the constraint of using λ max /3 as the Dc value.…”
Section: Tests and Data Validationsupporting
confidence: 86%
“…The sample parameters can be obtained from the fitting result of the life curve as: n constant = 12.83, D constant = 3.42×10 21 . This is consistent with the n = 12.2 obtained in previous studies [6].…”
Section: Obtaining N Values By Constant Stress Testmentioning
confidence: 99%