2021
DOI: 10.1016/j.molliq.2020.115119
|View full text |Cite
|
Sign up to set email alerts
|

Ionic liquid assisted synthesis of h-MoO3 hollow microrods and their application for electrochemical sensing of Imidacloprid pesticide in vegetables

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 64 publications
0
11
0
Order By: Relevance
“…It showed good sensitivity with detection limits of about 5.9 and 8.3 µM for differen-tial pulse voltammetry (DPV) and CV, respectively, and a wide linear range in both CV (38.7-114 µM) and DPV (38.7-132 µM). 50 In Table 1, some of the other ILs sensors and biosensors are listed.…”
Section: F I G U R E 1 Scheme Of Different Methods Used For the Fabri...mentioning
confidence: 99%
See 1 more Smart Citation
“…It showed good sensitivity with detection limits of about 5.9 and 8.3 µM for differen-tial pulse voltammetry (DPV) and CV, respectively, and a wide linear range in both CV (38.7-114 µM) and DPV (38.7-132 µM). 50 In Table 1, some of the other ILs sensors and biosensors are listed.…”
Section: F I G U R E 1 Scheme Of Different Methods Used For the Fabri...mentioning
confidence: 99%
“…This sensor was applied for the detection of imidacloprid pesticide, which is widely used for controlling insects in agricultural, urban, and industrial regions. It showed good sensitivity with detection limits of about 5.9 and 8.3 µM for differential pulse voltammetry (DPV) and CV, respectively, and a wide linear range in both CV (38.7–114 µM) and DPV (38.7–132 µM) 50 . In Table 1, some of the other ILs sensors and biosensors are listed.…”
Section: Application Of Ils In Electrochemical Sensorsmentioning
confidence: 99%
“…However, high concentrations of PA are highly corrosive, and this initiated major problems that included damaging the mechanical structure of the cells. Additionally, at higher temperatures, hydration of phosphoric acid and formation of pyrophosphoric acid oligomers reduced the conductivity of PA/PBI [102][103][104]. Therefore, several approaches were proposed, and recently, ILs were presented as a promising solution.…”
Section: Ionic Liquids In Pbi Membranesmentioning
confidence: 99%
“…The active surface area of the modified GCE was determined using 1 mM ferrocene, a standard redox couple in 0.1M KCl as the supporting electrolyte at room temperature, and Randles-Ševčik equation. For a reversible redox process, the peak current is expressed as ip = 2.69 ×10 5 n 3/2 ADapp 1/2 Coν 1/2 (5) where ip represents anodic peak current, n = 1 is number of electrons transferred, A is active surface area of electrode, Dapp = 0.16×10 -6 cm 2 s -1 is diffusion coefficient of ferrocene [29], ν is potential scan rate and Co is bulk concentration of ferrocene (1 mM). The active surface area of the modified electrode is determined as 0.54 cm 2 , which is about 7 times greater than the geometric area (0.0707 cm 2 ) of bare GCE.…”
Section: Synthesis Of Ionic Liquid Assisted Moo3mentioning
confidence: 99%