2020 42nd Annual International Conference of the IEEE Engineering in Medicine &Amp; Biology Society (EMBC) 2020
DOI: 10.1109/embc44109.2020.9176134
|View full text |Cite
|
Sign up to set email alerts
|

iQuant Auto: Automated Rapid Test Platform for Immunodiagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…This experiment was designed to investigate the CRISPR-based dFnCas9 detection of the Leptospira lipL32 gene using the lateral flow immunoassay strip, which involved dispensing capture biomolecules onto the test lines of the NC membrane, the addition of Alexa-labelled biomolecules on to the conjugate pads, cartridge assembly, and running of samples containing with the adequate sample biomolecules. The typical test procedure involved the addition of 90 µL of the appropriate lateral flow chase buffer to the sample pad of the LFIA cartridge, which was subsequently inserted into the iQuant analyzer [ 21 ]. The process was monitored for about 15 min.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This experiment was designed to investigate the CRISPR-based dFnCas9 detection of the Leptospira lipL32 gene using the lateral flow immunoassay strip, which involved dispensing capture biomolecules onto the test lines of the NC membrane, the addition of Alexa-labelled biomolecules on to the conjugate pads, cartridge assembly, and running of samples containing with the adequate sample biomolecules. The typical test procedure involved the addition of 90 µL of the appropriate lateral flow chase buffer to the sample pad of the LFIA cartridge, which was subsequently inserted into the iQuant analyzer [ 21 ]. The process was monitored for about 15 min.…”
Section: Methodsmentioning
confidence: 99%
“…Upon DNA loading, an automatic sandwiched assay was completed within 15 min, allowing for ultra-specific assay compared to other sensors enabling on-field analysis or bedside testing. The lateral flow paper strip was used on the quantitative strip reader iQuant developed at the Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras, India [ 19 , 20 , 21 ]. The advantages of the reader and performance comparison with other systems can be found in the literature [ 19 ].…”
Section: Introductionmentioning
confidence: 99%