2004
DOI: 10.1016/j.jmr.2003.09.015
|View full text |Cite
|
Sign up to set email alerts
|

J-modulated ADEQUATE (JM-ADEQUATE) experiment for accurate measurement of carbon–carbon coupling constants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
36
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 46 publications
(36 citation statements)
references
References 39 publications
0
36
0
Order By: Relevance
“…We have recorded ω 1 -refocused J-modulated 1,1-ADEQUATEs using BIPs with scaling factors of 5, 10 and 20 and have not observed any deviations of line shapes or coupling constants (except the normal scatter of values). Larger scaling factors lead -as observed previously 23 -to increasing relaxation and therefore, a balance between precision of the coupling constant and signal intensity has to be found.…”
Section: Resultsmentioning
confidence: 81%
See 2 more Smart Citations
“…We have recorded ω 1 -refocused J-modulated 1,1-ADEQUATEs using BIPs with scaling factors of 5, 10 and 20 and have not observed any deviations of line shapes or coupling constants (except the normal scatter of values). Larger scaling factors lead -as observed previously 23 -to increasing relaxation and therefore, a balance between precision of the coupling constant and signal intensity has to be found.…”
Section: Resultsmentioning
confidence: 81%
“…multiplet structure/intensity. As proposed recently, 23,24 we chose smoothed chirp pulses 25 (500 µs, 60 kHz sweep width) for all inversion 180°and composite smoothed chirp pulses 26 (2 ms total duration, 1 : 2:1, 500 µs, 1 ms, 500 µs, 60 kHz sweep width) for all refocusing pulses including the refocusing pulse in the J-modulation spin echo ( Fig. 2(a)).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 1. Carbon-carbon coupling constants of 1, in Hz, determined from in-and antiphase spectra of the isotropic and aligned sample Using the same sample, spectrometer, and identical experimental time, a 1 H-detected J-modulated IPAP-INADEQUATE experiment combining the existing Jmodulated INADEQUATE experiments 10,11 yielded S/N ratio of 8 : 1 (no window function in F 1 , data not shown). General reasons for such a good performance of the 13 C-detected INADEQUATE were discussed previously.…”
Section: Resultsmentioning
confidence: 98%
“…The determination of n J CC coupling constants is however non trivial, as partial cancellation of closely spaced antiphase lines produces an apparent splitting that is larger than the true coupling constant. 11,20,21 The use of inverse FT methods 22,23 in the analysis of antiphase doublets is also problematic. These methods rely on significant presence of the signal after the zero crossing, which is difficult to achieve in noise INADEQUATE cross peaks containing small coupling constants.…”
Section: Resultsmentioning
confidence: 99%