2014
DOI: 10.1016/j.tiv.2014.02.014
|View full text |Cite
|
Sign up to set email alerts
|

KeraSkin™-VM: A novel reconstructed human epidermis model for skin irritation tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
40
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 66 publications
(44 citation statements)
references
References 12 publications
2
40
0
2
Order By: Relevance
“…Of note, the activities of 1000 μg/mL (-)-4OH-ST ( 1 ) were comparable to those of 20,000 μg/mL kojic acid, suggesting that (-)-4OH-ST ( 1 ) may be active in humans. The toxicity of (-)-4OH-ST was further investigated in a 3D reconstituted human epidermis model, Keraskin™ (Biosolution Co, Seoul, Korea) [21], which showed little effects on tissue viability (Figure 6c).…”
Section: Resultsmentioning
confidence: 99%
“…Of note, the activities of 1000 μg/mL (-)-4OH-ST ( 1 ) were comparable to those of 20,000 μg/mL kojic acid, suggesting that (-)-4OH-ST ( 1 ) may be active in humans. The toxicity of (-)-4OH-ST was further investigated in a 3D reconstituted human epidermis model, Keraskin™ (Biosolution Co, Seoul, Korea) [21], which showed little effects on tissue viability (Figure 6c).…”
Section: Resultsmentioning
confidence: 99%
“…The testing methods base on these four models have been referred to define the alternative test methods endorsed by OECD to assess skin corrosion and skin irritation . In addition, other culture skin models, such as the Leiden reconstructed human epidermal model, the KeraSkin ™ model and epiCS ™ model, have been reported in the evaluation and validation efforts for in vitro skin tolerance testing according to ECVAM performance standard .…”
Section: Discussionmentioning
confidence: 99%
“…The testing methods base on these four models have been referred to define the alternative test methods endorsed by OECD to assess skin corrosion and skin irritation [11,12,14,16,22,[27][28][29][30]. In addition, other culture skin models, such as the Leiden reconstructed human epidermal model, the KeraSkin TM model and epiCS TM model, have been reported in the evaluation and validation efforts for in vitro skin tolerance testing according to ECVAM performance standard [10,31,32]. China EpiSkin model was reconstructed with keratinocytes of Chinese origin, and this is the first Chinese reconstructed human epidermis model to meet the high quality standard with industrialized production criteria.…”
Section: Discussionmentioning
confidence: 99%
“…Four RhE models, EpiSkin ™ , EpiDerm ™ SIT (EPI-200), the SkinEthic ™ RhE, and LabCyte EPI-MODEL24 SIT were accepted as OECD TG 439 (85) and Keraskin ™ was in the pre-validation stage (86). Generally RhE SIT is similar in procedure with some minor difference to optimize the predictive capacity (Table 2).…”
Section: Alternatives To Draize Rabbit Skin Irritation Testmentioning
confidence: 99%
“…After exposed for 45 min, the tissues were rinsed with D-PBS. Tissues were post-incubated for 42 hr and then evaluated viability with MTT assay (86). …”
Section: Alternatives To Draize Rabbit Skin Irritation Testmentioning
confidence: 99%