2015
DOI: 10.1016/j.optcom.2015.01.028
|View full text |Cite
|
Sign up to set email alerts
|

Label-free biosensing using cascaded double-microring resonators integrated with microfluidic channels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(18 citation statements)
references
References 26 publications
0
18
0
Order By: Relevance
“…For example, human immunoglobulin G (IgG) has been detected in microfluidic devices by detecting the refraction index change which was caused by the binding of secondary antibodies. This platform can be used in specific configured IgG detection for certain diseases diagnosis . Moreover, specific antibody to Helicobacter pylori (the main pathogens in enteritis) has also detected on a laser‐assisted microfluidic system for enteritis diagnosis ( Figure A) .…”
Section: Immunodiagnosis Studies On Microfluidic Chipsmentioning
confidence: 99%
“…For example, human immunoglobulin G (IgG) has been detected in microfluidic devices by detecting the refraction index change which was caused by the binding of secondary antibodies. This platform can be used in specific configured IgG detection for certain diseases diagnosis . Moreover, specific antibody to Helicobacter pylori (the main pathogens in enteritis) has also detected on a laser‐assisted microfluidic system for enteritis diagnosis ( Figure A) .…”
Section: Immunodiagnosis Studies On Microfluidic Chipsmentioning
confidence: 99%
“…Purely dielectric micro-rings and disks have been proposed and widely investigated as nano-sensors during the last decade. 1,[62][63][64][65][66][67][68][69][70][71][72][73][74][75][76][77][78][79][80] These systems are very good candidates for the integration on a compact chip. Here several rings can work in parallel in a multiplex architecture.…”
Section: Hybrid Wgm Ring and Disks For Bulk Refractive Index And Surfmentioning
confidence: 99%
“…In these cases the surface of the ring has to be properly functionalized. 1,62,63,65,66,68,69,71,[74][75][76][77]80 Two examples of bulk refractive index sensing (with a solution of water and sodium chloride) and surface binding (with the biotin/ streptavidin complex) are reported in Fig. 8.…”
Section: Hybrid Wgm Ring and Disks For Bulk Refractive Index And Surfmentioning
confidence: 99%
“…Photonic integrated circuits are now playing a role in advanced technologies with applications ranging from atmospheric spectroscopy [2] and medical diagnostics [3][4][5][6][7] to telecommunications [8,9], data centers, [10,11] and supercomputers [12,13]. Each of these integrated photonic application spaces opens new possibilites for science and technology.…”
Section: Introductionmentioning
confidence: 99%