2019
DOI: 10.1016/j.ab.2019.113449
|View full text |Cite
|
Sign up to set email alerts
|

Label-free lateral flow assay for Listeria monocytogenes by aptamer-gated release of signal molecules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 52 publications
(19 citation statements)
references
References 23 publications
0
19
0
Order By: Relevance
“…The high catalytic activity of HRP has led to its application in the LFA to improve the assay's sensitivity. Ozalp's group [ 95 ] immobilized HRP in the test zone of an LFA to indicate whether the target was present. In that study, after the interaction between the target bacterial cells and the aptamer in the conjugation zone of the LFA, TMB was released and migrated to test zone, where HRP converted the free TMB into blue particles.…”
Section: Labeling Materials Used In Lateral Flow Assaysmentioning
confidence: 99%
“…The high catalytic activity of HRP has led to its application in the LFA to improve the assay's sensitivity. Ozalp's group [ 95 ] immobilized HRP in the test zone of an LFA to indicate whether the target was present. In that study, after the interaction between the target bacterial cells and the aptamer in the conjugation zone of the LFA, TMB was released and migrated to test zone, where HRP converted the free TMB into blue particles.…”
Section: Labeling Materials Used In Lateral Flow Assaysmentioning
confidence: 99%
“…The production, labeling, amplification, and modification processes are also easier in aptamers in comparison to antibodies. Recently, aptamer‐functionalized AuNPs and aptamer‐gated silica NPs have been used to improve the sensitivity of LFA (Dalirirad & Steckl, 2019; Tasbasi et al., 2019).…”
Section: Poc Testing Devicesmentioning
confidence: 99%
“…dynamic light scattering immunoassay, lateral-flow enzyme immunoconcentration, enzyme-linked immunosorbent assay and quartz crystal microbalance immunosensor) have been developed for LM detection. 4,[8][9][10][11] There is no doubt that these method were very important in detecting LM, while they are easy to suffer from some defects either time-consuming, expensive equipment or complex operation. Compared to the general methods, the electrochemical technology has many incomparable merits since it's very simple, low-cost, easy to operate, and time-saving.…”
Section: Introductionmentioning
confidence: 99%