2016
DOI: 10.1007/s40940-016-0033-2
|View full text |Cite
|
Sign up to set email alerts
|

Laminated connections for structural glass components: a full-scale experimental study

Abstract: The use of glass material for structural components has drastically increased in the last decade. Among others, a laminated connection is a type of adhesive joint that makes use of foil interlayer adhesive to transfer forces between glass and metal parts. In this work, the use of embedded laminated connections is studied as connection between glass beams. In particular, it is experimentally investigated the use of embedded connections laminated to make a moment joint between laminated glass beam segments. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
3

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 26 publications
0
9
0
3
Order By: Relevance
“…Several authors have investigated the mechanical response of SG-laminated components [27]- [36] and the SG-bulk material [37]- [44]. Conversely, studies on the resistance of SG laminated connections are rather limited.…”
Section: Literature On Ionomer Sentryglas® (Sg) and Sg Connectionsmentioning
confidence: 99%
“…Several authors have investigated the mechanical response of SG-laminated components [27]- [36] and the SG-bulk material [37]- [44]. Conversely, studies on the resistance of SG laminated connections are rather limited.…”
Section: Literature On Ionomer Sentryglas® (Sg) and Sg Connectionsmentioning
confidence: 99%
“…Several authors have investigated the mechanical response of SG-laminated components [33]- [44] and the SG-bulk material [12], [45]- [51]. Conversely, studies on the resistance of SG laminated connections are rather limited.…”
Section: Ionomer Sentryglas® (Sg)mentioning
confidence: 99%
“…Another application of embedded laminated connections can also be found in London, at the new Tottenham Court Road underground station . Finally − even currently limited to academic research − full‐scale investigations for LG beam‐to‐beam applications with laminated connections can be found in ref . Three different configurations of the embedded connections (i.e., with variations in their geometry and position) were tested.…”
Section: Overview Of Existing Research and Applications On Full‐scalementioning
confidence: 99%