2010
DOI: 10.1016/j.eururo.2009.07.023
|View full text |Cite
|
Sign up to set email alerts
|

Laparo-Endoscopic Single Site (LESS) versus Standard Laparoscopic Left Donor Nephrectomy: Matched-pair Comparison

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
157
1
5

Year Published

2011
2011
2018
2018

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 241 publications
(165 citation statements)
references
References 18 publications
2
157
1
5
Order By: Relevance
“…Two retrospective matched-pair comparison of LESS to standard laparoscopic live-donor nephrectomy have been recently reported [70,71] (Table 7). Canes et al performed this LESS procedure through an intra-umbilical multichannel port, using a 5-mm rigid laparoscope with integrated camera head, with standard and curved/articulating instruments [70].…”
Section: Laparoendoscopic Single-site Surgery Versus Standard Laparosmentioning
confidence: 99%
See 2 more Smart Citations
“…Two retrospective matched-pair comparison of LESS to standard laparoscopic live-donor nephrectomy have been recently reported [70,71] (Table 7). Canes et al performed this LESS procedure through an intra-umbilical multichannel port, using a 5-mm rigid laparoscope with integrated camera head, with standard and curved/articulating instruments [70].…”
Section: Laparoendoscopic Single-site Surgery Versus Standard Laparosmentioning
confidence: 99%
“…Canes et al performed this LESS procedure through an intra-umbilical multichannel port, using a 5-mm rigid laparoscope with integrated camera head, with standard and curved/articulating instruments [70]. The kidney was extracted through a slightly extended umbilical incision.…”
Section: Laparoendoscopic Single-site Surgery Versus Standard Laparosmentioning
confidence: 99%
See 1 more Smart Citation
“…Desai et al reported 2 postoperative complications in a series of 17 predominantly left-sided LESS-DN [17]. Canes and colleagues reported 2 postoperative complications in their series of 18 consecutive LESS-DN [18]. In this study, only one case was a right-sided donor and was converted to standard laparoscopy and excluded from their analysis.…”
Section: Discussionmentioning
confidence: 76%
“…Furthermore, both of these studies report using an additional 2mm needlescopic grasper [16] or 5mm port for liver retraction [17], whereas we do not utilize any additional ports. In a more recent study comparing LESS-DN to conventional LAP-DN, operative times for each procedure far exceeded ours (269 minutes and 239 minutes, respectively) [18].…”
Section: Discussionmentioning
confidence: 99%