Purpose
It is difficult to maintain sufficient tension throughout laparoscopic anterior resection with total mesorectal excision, which causes a decline in surgical quality. We used a soft, inexpensive gauze pad band pulling the rectal tube to analyze the effect of surgery.
Methods
A gauze pad band was positioned at the proximal of the tumor, followed by fastening the rectal tube and ligating the rectum. 233 patients undergoing laparoscopic anterior resection for mid to low rectal cancer were enrolled between January 2018 and December 2020. After propensity score matching, 63 cases were selected in gauze pad band group and 126 cases were selected in traditional group. The two groups were compared in preoperative, intraoperative, and pathological characteristics.
Results
Compared to traditional group, the median operation duration (203 min vs. 233 min, p < 0.001) and the median intraoperative bleeding (48 ml vs. 67 ml, p < 0.001) were lesser in gauze pad band group. A higher percentage of one cartridge transection of rectum (36/63 vs. 51/126, p = 0.030), shorter length of cartridges used (6.88 ± 1.27 cm vs. 7.28 ± 1.25 cm, p = 0.040), and longer distal resection margin (2.74 ± 0.76 cm vs. 2.16 + 0.68 cm, p < 0.001) were found in the gauze pad band group. The completeness of total mesorectal excision (61/63 vs. 109/126, p = 0.022), harvested lymph nodes (19 vs. 17, p < 0.001) and positive lymph nodes (1 vs. 0, p = 0.046) were higher in gauze pad band group.
Conclusion
Ligation of the rectum with a gauze pad band allows for a reduction in operative time and intraoperative bleeding while increasing the rate of one cartridge transection. It also protected the quality of total mesorectal excision and membrane anatomy.
Trial registration: Not applicable.