2014
DOI: 10.1007/978-981-4585-30-9
|View full text |Cite
|
Sign up to set email alerts
|

Large Scale Renewable Power Generation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Although this proposal simplifies the short-circuit calculations significantly, it seems unlikely that the CBDG can provide a steady state short-circuit current of 2 pu. In [20], short-circuit simulations on type 4 wind turbines (full-conversion AC-AC wind turbines) were performed. The results illustrate that at fault initiation, there is a transient current peak reaching values up to 1.6 pu after which the current drops to steady state in less than one cycle.…”
Section: Fault Current Contribution Of Cbdgsmentioning
confidence: 99%
“…Although this proposal simplifies the short-circuit calculations significantly, it seems unlikely that the CBDG can provide a steady state short-circuit current of 2 pu. In [20], short-circuit simulations on type 4 wind turbines (full-conversion AC-AC wind turbines) were performed. The results illustrate that at fault initiation, there is a transient current peak reaching values up to 1.6 pu after which the current drops to steady state in less than one cycle.…”
Section: Fault Current Contribution Of Cbdgsmentioning
confidence: 99%
“…Multilevel converters have been proposed and used to overcome some of the previously discussed problems [12,[19][20][21][22][23]. Multilevel converters show interesting features like direct integration to the MV grid if a suitable number of levels are applied; therefore, this converter could be considered a transformer-less converter for MV-grid integration [11,24,25]. Due to the high number of levels in a staircase form, the waveform in the converter's output is closer to a sinusoidal signal; this implies that the THD could be minimal [10,25,26].…”
Section: Introductionmentioning
confidence: 99%
“…Multilevel converters show interesting features like direct integration to the MV grid if a suitable number of levels are applied; therefore, this converter could be considered a transformer-less converter for MV-grid integration [11,24,25]. Due to the high number of levels in a staircase form, the waveform in the converter's output is closer to a sinusoidal signal; this implies that the THD could be minimal [10,25,26]. The two formers features can be achieved without using high-rated voltage switches; in other words, to achieve the MV levels and a low THD, commercial switches can be implemented [10].…”
Section: Introductionmentioning
confidence: 99%
“…For the probabilistic approach, historical measurements, theoretical modelling or synthetic profiles can be considered to calculate the probability density function of input variables (Soroudi, 2014).…”
Section: Introductionmentioning
confidence: 99%