2022
DOI: 10.1007/s00604-022-05566-1
|View full text |Cite
|
Sign up to set email alerts
|

Laser-scribed graphene on polyetherimide substrate: an electrochemical sensor platform for forensic determination of xylazine in urine and beverage samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 51 publications
0
14
0
Order By: Relevance
“…However, this technique is expensive and time-consuming, prompting the development of alternative approaches like Xylazine test strips, which provide a more cost-effective and rapid means for presumptive testing [ 66 ]. Other proposed solutions involve novel electrochemical sensor platforms like a laser-scribed graphene device [ 67 ] or an electrochemical paper-based analytical device [ 68 ].…”
Section: Reviewmentioning
confidence: 99%
“…However, this technique is expensive and time-consuming, prompting the development of alternative approaches like Xylazine test strips, which provide a more cost-effective and rapid means for presumptive testing [ 66 ]. Other proposed solutions involve novel electrochemical sensor platforms like a laser-scribed graphene device [ 67 ] or an electrochemical paper-based analytical device [ 68 ].…”
Section: Reviewmentioning
confidence: 99%
“…A complementary characterization of each functionalization step was performed by the contact angle (Figure D). The bare LSG electrode presented a moderate hydrophilic surface of 52.65 ± 2.40° (black dot) related to few interactions with water since the unmodified surface is predominantly graphene derivative in its composition . Then, the electrodeposition of AuNS increased the contact angle values of the electrode to 61.73 ± 1.02° (red dot), which was expected due to the presence of a metallic surface .…”
Section: Resultsmentioning
confidence: 87%
“…The bare LSG electrode presented a moderate hydrophilic surface of 52.65 ± 2.40°(black dot) related to few interactions with water since the unmodified surface is predominantly graphene derivative in its composition. 34 Then, the electrodeposition of AuNS increased the contact angle values of the electrode to 61.73 ± 1.02°(red dot), which was expected due to the presence of a metallic surface. 57 Next, the immobilization of MPXV antibodies leaves the surface with several organic groups (−NH 2 , −NH, −COOH, −COC−, etc.…”
Section: Design and Characterization Of The Disposable Electrochemicalmentioning
confidence: 80%
See 2 more Smart Citations