2022
DOI: 10.1016/j.jse.2021.07.022
|View full text |Cite
|
Sign up to set email alerts
|

Lateralized vs. classic Grammont-style reverse shoulder arthroplasty for cuff deficiency Hamada stage 1-3: does the design make a difference?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
6
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 44 publications
1
6
0
1
Order By: Relevance
“…In a similar study focused on Hamada Grade 1 to 3 cuff-deficient shoulders better external rotation and a trend towards better internal rotation with less scapular notching for lateralized (135° NSA and 4 mm lateralized glenosphere) over non-lateralized RSAs (155° NSA and 2 mm eccentric glenosphere) was reported [ 26 ]. The use of curved stem 145° NSA onlay designs introduced another type of RSA configuration; a computational ROM study for different humeral and glenosphere design concepts showed adequate restoration of glenohumeral ROM only for a lateralized NSA (145°) in combination with eccentric, large or lateralized spheres [ 14 ].…”
Section: Discussionmentioning
confidence: 99%
“…In a similar study focused on Hamada Grade 1 to 3 cuff-deficient shoulders better external rotation and a trend towards better internal rotation with less scapular notching for lateralized (135° NSA and 4 mm lateralized glenosphere) over non-lateralized RSAs (155° NSA and 2 mm eccentric glenosphere) was reported [ 26 ]. The use of curved stem 145° NSA onlay designs introduced another type of RSA configuration; a computational ROM study for different humeral and glenosphere design concepts showed adequate restoration of glenohumeral ROM only for a lateralized NSA (145°) in combination with eccentric, large or lateralized spheres [ 14 ].…”
Section: Discussionmentioning
confidence: 99%
“…Although numerous implant designs with various magnitudes of lateralization have been advocated 2,6-8 , most reports have been case series. According to our review of the literature, there have been 14 studies comparing lateralized RSA with nonlateralized RSA of the equivalent design (Table III) 14,[23][24][25][26][27][28][29][30][31][32][33][34][35] .…”
Section: Discussionmentioning
confidence: 99%
“…Although numerous implant designs with various magnitudes of lateralization have been advocated 2,6-8 , most reports have been case series. According to our review of the literature, there have been 14 studies comparing lateralized RSA with nonlateralized RSA of the equivalent design (Table III) 14,23-35 . Although the scapular notching rate was reduced, most reported no significant differences in range of motion and functional scores between the lateralized RSA and its nonlateralized control (Table III).…”
Section: Discussionmentioning
confidence: 99%
“…Dies zeigt sich ebenfalls in den ersten Studien, die durch eine humerale Verkleinerung des Inklinationswinkels einen signifikanten Rückgang des skapulären Notchings (155°= 66 % versus 135°= 33 %) bestätigten [17,18].…”
Section: Merkeunclassified