1998
DOI: 10.1016/s0584-8547(97)00138-9
|View full text |Cite
|
Sign up to set email alerts
|

Lead speciation in rainwater by isotope dilution-high performance liquid chromatography-inductively coupled plasma-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(25 citation statements)
references
References 59 publications
0
25
0
Order By: Relevance
“…158 This technique has also been applied to iodine determination in humic substances, 159 as well as selenium speciation in human serum. 160 Species-specific isotope dilution using HPLC-ICP-MS has been described for selenium analysis, 80 the analysis of organotin species in sediments, 161,162 methylmercury in fish tissue, 163 trimethyllead in water, 164 and chromium speciation. 13 Overviews to this topic have been published, e.g.…”
Section: Isotope Dilution In Speciation With Hplc-icp-msmentioning
confidence: 99%
“…158 This technique has also been applied to iodine determination in humic substances, 159 as well as selenium speciation in human serum. 160 Species-specific isotope dilution using HPLC-ICP-MS has been described for selenium analysis, 80 the analysis of organotin species in sediments, 161,162 methylmercury in fish tissue, 163 trimethyllead in water, 164 and chromium speciation. 13 Overviews to this topic have been published, e.g.…”
Section: Isotope Dilution In Speciation With Hplc-icp-msmentioning
confidence: 99%
“…The method is analogous to the standard addition technique in that the sample is spiked with a known quantity of analyte material, and resembles the internal standardization procedure, with the exception that the analyte itself is the internal standard. To use this method, two or more isotopes of the analyte must be available for the measurement since one of the isotopes is in the added spike [18,19]. This approach can compensate for biases caused by instrumental drift as well as for sample loss during the preparation.…”
Section: Tatiana Trejos · Shirly Montero · José R Almirallmentioning
confidence: 99%
“…After equilibration, the modified analyte isotope ratio is measured and the concentration of the analyte in the original sample can be calculated by [19]:…”
Section: Quantitative Analysis For Id-icp-msmentioning
confidence: 99%
“…Coupling of GC [14][15][16][17][18][19][20][21][22] or HPLC [23][24][25][26] to ICP-MS has provided sensitive and powerful techniques for butyltin determinations. More recently, species specific isotope dilution has been applied to the determination of butyltins [18][19][20][25][26][27] and other organometallic species, including organolead 25,26,28 and methylmercury [29][30][31] for more accurate and precise results, using synthesized speciesspecific spikes. Among these studies, qICP-MS has been the choice as a detector due to its relatively fast sampling speed for acquiring transient signals and its simplicity in use compared with early SF-ICP-MS instruments.…”
Section: Introductionmentioning
confidence: 99%