Left atrial appendage closure device implantation in patients at very high risk for stroke

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…Hence, it would be reasonable to propose that LAAO devices lead to a similar if not better outcome when it comes to stroke prevention compared to OAC. Numerous other studies also support this argument [8,13,14]. To date, the most aggressively evaluated LAAO device is the Watchman device.…”
Section: Figure 1: Safety Concerns With Laao and Oacmentioning
confidence: 88%
See 1 more Smart Citation
“…Hence, it would be reasonable to propose that LAAO devices lead to a similar if not better outcome when it comes to stroke prevention compared to OAC. Numerous other studies also support this argument [8,13,14]. To date, the most aggressively evaluated LAAO device is the Watchman device.…”
Section: Figure 1: Safety Concerns With Laao and Oacmentioning
confidence: 88%
“…For these patients, LAAO has emerged as a nonpharmacological alternative for the prevention of stroke [6,7]. The two devices most commonly used in clinical practice are the Watchman® and Amulet® (Amplatzer) devices, but randomized studies are only available for the Watchman device [8].…”
Section: Introductionmentioning
confidence: 99%
“…Except for one study by Urena et al [ 9 ] and the high-risk population of Hutt et al [ 10 ], the thromboembolic risk in the Austrian LAAC registry, as predicted by the CHA 2 DS 2 -VASc score (median 5) or CHADS 2 score (median 3), was higher than in previous studies, which report a median CHA 2 DS 2 -VASc score of 4 [ 3 , 11 , 12 , 13 , 14 , 15 , 16 , 17 ] or a median CHADS 2 score of 2 [ 18 , 19 ]. The bleeding risk assessed by the HAS-BLED score was comparable to previous literature (median 3) [ 13 , 14 , 15 , 16 , 17 ].…”
Section: Discussionmentioning
confidence: 99%
“…53 Wazni and colleagues recently reported the feasibility and safety of WATCHMAN device implantation in 104 consecutive patients with CHADS2VASC > 5. 54 The residual annual stroke risk was 2.8% following WATCHMAN implant, compared to a 4% annual estimated risk of stroke on VKA. It is unclear to what extent residual stroke risk in patients with AF on OAC is secondary to noncardioembolic sources of stroke.…”
Section: Elevated Residual Stroke Riskmentioning
confidence: 94%
“…Many patients with AF and higher stroke risk, particularly those with permanent AF or concomitant HF, have significant residual stroke risk despite anticoagulation . Wazni and colleagues recently reported the feasibility and safety of WATCHMAN device implantation in 104 consecutive patients with CHADS2VASC > 5 . The residual annual stroke risk was 2.8% following WATCHMAN implant, compared to a 4% annual estimated risk of stroke on VKA.…”
Section: Laac and Doac In Unique Subgroupsmentioning