Liberating Native Mass Spectrometry from Dependence on Volatile Salt Buffers by Use of Gábor Transform

Abstract: Volatile salts, such as ammonium acetate, are commonly used in buffers for the analysis of intact proteins and protein complexes in native electrospray ionization mass spectrometry. Although these solutions are not technically buffers near pH 7, the volatile nature of the salt minimizes ion adduction to proteins upon transfer to vacuum. Conversely, common biochemical salt buffers, such as Tris/NaCl, are not traditionally used in native mass spectrometry because of the tendency of sodium and other ions to adduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
31
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(31 citation statements)
references
References 43 publications
0
31
0
Order By: Relevance
“…The CRM is supported by the observation that the charge states of globular proteins are close to the Rayleigh charge of protein-sized water droplets . Also, the well-known tendency of protein ions to undergo nonspecific adduction to salts and other solutes under native ESI conditions , is consistent with solvent evaporation to dryness during the CRM. , …”
mentioning
confidence: 74%
“…The CRM is supported by the observation that the charge states of globular proteins are close to the Rayleigh charge of protein-sized water droplets . Also, the well-known tendency of protein ions to undergo nonspecific adduction to salts and other solutes under native ESI conditions , is consistent with solvent evaporation to dryness during the CRM. , …”
mentioning
confidence: 74%
“…Multiple approaches to ESI deconvolution have been developed, but there is no universal scoring scheme to judge the quality of the deconvolution. Early maximum entropy methods , remain common.…”
Section: Introductionmentioning
confidence: 99%
“…To overcome these challenges, multiple deconvolution software programs have been created to help assign charge states and deconvolve intact MS data. [15][16][17][18][19][20][21][22][23][24][25] A recent review has covered a wide variety of deconvolution software. [26] UniDec (Universal Deconvolution) software uses Bayesian deconvolution to quickly assign the charge states of m/z peaks and thus determine the mass.…”
Section: Introductionmentioning
confidence: 99%