1998
DOI: 10.1002/(sici)1099-159x(199803/04)6:2<127::aid-pip214>3.0.co;2-z
|View full text |Cite
|
Sign up to set email alerts
|

Life-cycle air emissions from PV power systems

Abstract: This paper addresses the air emissions of grid supply versus grid‐connected and off‐grid photovoltaic power generation, using the framework of life‐cycle assessment, in the context of rural household energy supply in Australia. Emissions of carbon dioxide, sulphur dioxide and nitrous oxides are calculated for the three life‐cycle stages of manufacture, use and disposal. Sensitivities to materials and data inputs, as well as to component efficiencies, lifetimes and sizing are discussed. For each supply option, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

1998
1998
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(16 citation statements)
references
References 5 publications
0
16
0
Order By: Relevance
“…With the energy payback time value of 4.9 years for design alternative No.1 and 6.0 years for design alternative No.2, the results are higher than the typical energy payback times of solar combisystems (without long-term storage capacity) ranging from 2.0 to 4.3 years [20]. Yet, such difference is easily explained by the higher overall efficiency of power plants in Quebec (73.1%) compared to Germany (35.0%).…”
Section: Life Cycle Energy Usementioning
confidence: 78%
See 1 more Smart Citation
“…With the energy payback time value of 4.9 years for design alternative No.1 and 6.0 years for design alternative No.2, the results are higher than the typical energy payback times of solar combisystems (without long-term storage capacity) ranging from 2.0 to 4.3 years [20]. Yet, such difference is easily explained by the higher overall efficiency of power plants in Quebec (73.1%) compared to Germany (35.0%).…”
Section: Life Cycle Energy Usementioning
confidence: 78%
“…The energy yield ratio (EYR) was defined as how many times the energy invested in the manufacturing of combisystem was returned by the system in its entire life span [20]. Higher ratio values show better performance.…”
Section: Life Cycle Energy Usementioning
confidence: 99%
“…There are still emissions from manufacturing, transportation and disposal throughout the life cycle of the system [6], [7], [8].…”
Section: Reducing Emissionsmentioning
confidence: 99%
“…Again the average carbon dioxide (CO 2 ) equivalent intensity of electricity generation from coal is approximately 0.982 kg of CO 2 /kWh at power plant [27,28]. Thus, for unit power consumption by the consumer the amount of CO 2 emission is 2.08×0.982=2.04 kg.…”
Section: Carbon Credit Earned By Pvt Mixed Mode Dryermentioning
confidence: 99%