2019
DOI: 10.1016/j.clae.2018.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Light disturbance analysis in the controlled randomized clinical trial MiSight® Assessment Study Spain (MASS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(36 citation statements)
references
References 22 publications
1
33
2
Order By: Relevance
“…This instrument reliably quantifies a subjective component of vision other than VA. 1,7 The LDA has been validated previously and used to assess light disturbance phenomena under dim-light conditions in eyes fitted with different optical devices. 1,2,8,19 In brief, the system consists of a central 5 mm white lightemitting diode (LED) surrounded by 240 small, white 1mm LEDs divided into 24 semi-meridians with an angular separation of 15 degrees and covering an area of 10 degrees at an examination distance of 2 m. A detailed description of the system, light sources and acquisition procedure has been reported previously. 20 For the purposes of the present study, semi-meridians with an angular separation of 30 degrees were analysed in order to reduce the time of examination.…”
Section: Light Disturbancementioning
confidence: 99%
See 2 more Smart Citations
“…This instrument reliably quantifies a subjective component of vision other than VA. 1,7 The LDA has been validated previously and used to assess light disturbance phenomena under dim-light conditions in eyes fitted with different optical devices. 1,2,8,19 In brief, the system consists of a central 5 mm white lightemitting diode (LED) surrounded by 240 small, white 1mm LEDs divided into 24 semi-meridians with an angular separation of 15 degrees and covering an area of 10 degrees at an examination distance of 2 m. A detailed description of the system, light sources and acquisition procedure has been reported previously. 20 For the purposes of the present study, semi-meridians with an angular separation of 30 degrees were analysed in order to reduce the time of examination.…”
Section: Light Disturbancementioning
confidence: 99%
“…Light disturbance can be caused by defocus, degradation of an optical system, scattering, opacities in optical media, diffraction or aberrations. 2,19,34 An increase in positive spherical aberration is related to an increase in light disturbance, while negative spherical aberrations are associated with lower levels of light disturbance. 15,37 Macedo-de-Araujo et al 37 reported that an increase of +0.15 lm in spherical aberration leads to an increase of between 10% and 20% in LDI.…”
Section: Light Disturbancementioning
confidence: 99%
See 1 more Smart Citation
“…These ndings show that the changes in HOA induced by dual-focus designs (such as MiSight) are substantially more pupil-dependent than the center-distance MFCL designs 31,34 and shows the role of SA whose magnitude differently affects the myopia control. 34 Previous MASS studies have also reported an increase on monocular light disturbance perception 28 and near-vision worsening 26 in subjects wearing MiSight (study group) compared with subjects wearing single-vision spectacles (control group). Nevertheless, over 2 years of follow-up there could be seen a signi cant binocular attenuation effect, and a consequent decrease in the monocular light disturbance.…”
Section: Discussionmentioning
confidence: 96%
“…should be used in the future as myopia control devices can induce some degree of dysphotopsia, particularly under dim lighting conditions [85,127].…”
Section: Visual Acuity and Dysphotopsiamentioning
confidence: 99%