1998
DOI: 10.2170/jjphysiol.48.197
|View full text |Cite
|
Sign up to set email alerts
|

Linear O2 Use-Pressure-Volume Area Relation from Curved End-Systolic Pressure-Volume Relation of the Blood-Perfused Rat Left Ventricle.

Abstract: We measured rat left ventricular pressure, volume, and oxygen consumption ( = arteriovenous oxygen content differencexcoronary flow) to establish a new evaluation of its mechanoenergetics in the whole heart preparation by using the cross-circulation method. We obtained a curved end-systolic pressure-volume relation in contrast to a linear end-systolic pressure-volume relation in dogs, rabbits, and humans. However, we obtained a linear oxygen consumption per beat (VO2)-systolic pressure-volume area (PVA, a meas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

27
128
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 37 publications
(155 citation statements)
references
References 9 publications
27
128
0
Order By: Relevance
“…If pacing rate is decreased, myocardial O 2 consumption per minute will decrease. As shown previously (6,7,32,33), the V O2-PVA relation was linear in the rat LV. Its slope represents the oxygen cost of PVA, the efficiency of chemical to mechanical energy transduction (29).…”
supporting
confidence: 83%
See 2 more Smart Citations
“…If pacing rate is decreased, myocardial O 2 consumption per minute will decrease. As shown previously (6,7,32,33), the V O2-PVA relation was linear in the rat LV. Its slope represents the oxygen cost of PVA, the efficiency of chemical to mechanical energy transduction (29).…”
supporting
confidence: 83%
“…The heartlung section was isolated from the left common carotid artery, descending aorta, inferior vena cava, and pulmonary trunk in this order. The beating heart was excised without interruption of coronary perfusion and supported by cross circulation with the metabolic supporter rat as previously reported in detail (6,7). The excised heart was maintained at 37°C.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…However, the cardiac mechanoenergetics studies have not yet been well conducted. We have established a method to analyze specifically the LV mechanical work and energetics in an excised, blood-perfused whole heart preparation with a cross-circulation method (7,14,17,19,20,24) and analyzed LV mechanoenergetics in a PO heart failure model.In the present study, we focused on the investigation of the mechanical work and energetics in a VO heart failure model with an arteriovenous (AV) shunt in rats. …”
mentioning
confidence: 99%
“…All rats were heparinized (1,000 units intravascular). The beating donor heart was excised without an interruption of coronary perfusion and supported by cross circulation with the other metabolic supporter rat as previously reported in detail (7,14,17,19,24). The coronary arterial oxygenated blood of the donor heart was supplied from the common carotid arteries of the supporter rat using arterial cross-circulation tubing and a cannula inserted into the brachiocephalic artery of the donor heart.…”
mentioning
confidence: 99%