Abstract:Time difference amplifiers are used in fluorescence experiments where the input time differences are in picoseconds. The key challenge is to provide the linearity of such amplifiers with sufficient gain over the required input range. This amplifier has a gain greater than 2 ps ps , with the input ranging from 10 pS to 1000 pS. The gain error is found to be less than 10% at a temperature of 25 • C , voltage range of 800mV to 1.2 V. The overall power consumption from simulation is 4 mW. This design uses differen… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.