2013
DOI: 10.1016/j.toxicon.2013.07.013
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography/negative electrospray ionization ion trap MS2 mass spectrometry application for the determination of microcystins occurrence in Southern Portugal water reservoirs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 42 publications
0
9
0
1
Order By: Relevance
“…Negative ionization mode by MALDI and ESI presented low absolute intensities but also low background and therefore provided suitable S/N ratios. According to other authors [19][20][21]44], as shown Table S1 of supplementary data, the analysis of MCs containing no Arg residue such as MC-LA, -LF, -LW and -LY presented high sensitivity in negative ionization mode.…”
Section: Throughput Analysis (Direct Maldi and Esi Analysis)mentioning
confidence: 81%
See 2 more Smart Citations
“…Negative ionization mode by MALDI and ESI presented low absolute intensities but also low background and therefore provided suitable S/N ratios. According to other authors [19][20][21]44], as shown Table S1 of supplementary data, the analysis of MCs containing no Arg residue such as MC-LA, -LF, -LW and -LY presented high sensitivity in negative ionization mode.…”
Section: Throughput Analysis (Direct Maldi and Esi Analysis)mentioning
confidence: 81%
“…The main fragment ions of MC-LR have been included in Table 2. These fragment ions have been already described in the literature [19,21,52] but in the present manuscript all the fragment ions have been evaluated for confirmatory purposes. As shown in Fig.…”
Section: Tablementioning
confidence: 99%
See 1 more Smart Citation
“…Tandem mass spectrometry (MS/MS) has been widely adopted for the routine quantitative analyses of target cyanotoxins in water samples using the very sensitive multiple reaction monitoring (MRM) mode of triple quadrupole (QqQ) mass spectrometers [23,[25][26][27][28][29][30][31]. For structural characterization and quantitation purposes, 3D ion trap (IT) [32][33][34][35][36][37], linear ion trap (LIT) [38], time-of-flight (TOF) [39,40], Q-TOF [41][42][43][44][45] and Orbitrap mass spectrometers [26,[46][47][48][49][50][51][52] were employed. High mass accuracy of TOF and Orbitrap instruments is beneficial for LC-MS and LC-MS/MS analyses of cyanotoxins [24].…”
Section: Introductionmentioning
confidence: 99%
“…Sendo assim, um espectrômetro de massas consiste em uma fonte de ionizaçaõ para a obtençaõ de ións, um analisador de massas, o qual separa os ións formados, um detector desses ións e um sistema de aquisiçaõ dos dados(CAIXACH et al, 2017). outras moléculas como uma abordagem padrão para fins quantitativos, embora o ESI modo negativo também tenha sido usado para análise de certas cianotoxinasGAMBARO et al, 2012;RODRIGUES;REIS;MATEUS, 2013). Nodularia spumigena CENA596 encontrada no oceano Atlântico Sul do Brasil apresenta diversidade de agrupamentos gênicos envolvidos na síntese de moléculas bioativas e diferenças significativas quando comparado com o único genoma disponível dessa espécie, a Nodularia spumigena CCY9414 originária do mar Báltico.A redução de bactérias contaminantes na cultura da N. spumigena CENA596 foi feita conforme a metodologia apresentada porVaz et al (2014).…”
unclassified