2021
DOI: 10.1016/j.apacoust.2020.107787
|View full text |Cite
|
Sign up to set email alerts
|

Liquid lens with adjustable focus for ultrasonic imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…The laboratory multi-function ultrasonic testing system based on LabView software was a high precision test platform ( Li et al, 2021a , c ). Based on the platform, the emission acoustic fields of ultrasonic transducers with different structures were measured at 400 kHz.…”
Section: Methods and Resultsmentioning
confidence: 99%
“…The laboratory multi-function ultrasonic testing system based on LabView software was a high precision test platform ( Li et al, 2021a , c ). Based on the platform, the emission acoustic fields of ultrasonic transducers with different structures were measured at 400 kHz.…”
Section: Methods and Resultsmentioning
confidence: 99%
“…With the help of COMSOL software, Peng et al [ 45 ] proposed an ultrafast ultrasound imaging system for capturing mobile microbubbles, as shown in Figure 6 C, which could be used to control drugs in an accurate location for clinical use. Similarly, Li et al [ 46 ] designed and fabricated an acoustic liquid lens using COMSOL software for a PUT and improved the imaging performance, as shown in Figure 6 D. The results showed that the acoustic liquid lens combined with a 6.8 MHz PUT had a tunable focus, which made accurate imaging in different conditions possible.…”
Section: Traditional Optimization Design Methods For a Putmentioning
confidence: 93%
“… Efficient optimization design software should be developed by integrating the predictive models and intelligent optimization algorithms. Most optimization design methods are developed for a low-frequency PUT [ 28 , 36 , 37 , 40 , 46 ], therefore, an efficient optimization design method for a high-frequency PUT should be proposed and developed in the future. …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There is an unconventional, but very interesting lens, as shown in Supplementary Figure S14. It can flexibly change the focus point by injecting liquid to control the curvature of the lens (Li et al, 2021b;Li et al, 2021c). It is hard to apply in UHF ultrasonic devices, but some special occasions may play a miraculous effect.…”
Section: Adjustable Focusmentioning
confidence: 99%